Dynamic Changes in Implantable Collamer Lens Vault and Anterior Chamber Angle Under Varying Lighting Conditions

Matthew Hirabayashi,1,2 Eric C Cantu,1 Andrew J Abramson,3 Gurpal Virdi,4 Taj Nasser,5 Gregory Parkhurst1,2 1Parkhurst NuVision LASIK Eye Surgery, San Antonio, TX, USA; 2Amarillo NuVision, Amarillo, TX, USA; 3Texas State University, San Marcos, TX, USA; 4Mason Eye Institute, University of Missouri, Columbia, MO, USA; 5Tylock Nasser Vision, Irvine, TX, USACorrespondence: Matthew Hirabayashi, Parkhurst NuVision LASIK Eye Surgery, 9725 Datapoint Dr Suite 106, San Antonio, TX, 78229, USA, Tel +1 314 578 2374, Email [email protected]: To evaluate the effect of lighting conditions on Implantable Collamer Lens (ICL) vault and anterior chamber angle measurements using the MS-39, and to determine whether vault variability correlates with average vault or ICL power.Methods: A retrospective analysis was performed on 100 eyes from 53 patients who underwent EVO or EVO Toric ICL implantation. Postoperative anterior segment imaging was conducted using the MS-39 device under scotopic, mesopic, and photopic lighting. Vault and anterior chamber angles were measured, with angle values derived from the mean of the nasal and temporal readings along the 180° axis. A Friedman and ANOVA test assessed changes in measurements across lighting conditions. Pearson and Spearman correlation was used to evaluate relationships between vault variability, mean vault, and ICL power.Results: Mean vault significantly decreased under photopic conditions (393.8 ± 165.6 μm) compared to mesopic (486.7 ± 185.5 μm) and scotopic (495.6 ± 187.7 μm) states (p < 0.0001). Angle measurements increased significantly under brighter lighting (p < 0.0001). Vault variability positively correlated with mean vault (ρ = 0.395, p < 0.0001), while ICL power showed a weak negative correlation (ρ = − 0.224, p = 0.025).Conclusion: ICL vault and anterior chamber angle measurements vary meaningfully with lighting conditions. Eyes with higher vaults exhibit greater variability, while lower vaults demonstrated less variability across lighting conditions. ICL power may have a small but weak influence on vault dynamics. These findings may help refine ICL sizing strategies and postoperative assessment protocols.Keywords: refractive surgery, vision correction, phakic IOLs, vault, sizing

Authors

Publication Details

Journal
Dove Medical Press (Taylor and Francis Group)
Published
2026-04-30
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Changes in Implantable Collamer Lens Vault and Anterior Chamber Angle Under Varying Lighting Conditions

Matthew Hirabayashi, Gregory Parkhurst, Andrew Abramson, Eric Cantú et al.
Dove Medical Press (Taylor and Francis Group)
Corneal surgery and disorders
article

Dynamic Changes in Implantable Collamer Lens Vault and Anterior Chamber Angle Under Varying Lighting Conditions

Matthew Hirabayashi, Gregory Parkhurst, Andrew Abramson, Eric Cantú, Gurpal Virdi, Taj Nasser
article en

Abstract

Matthew Hirabayashi,1,2 Eric C Cantu,1 Andrew J Abramson,3 Gurpal Virdi,4 Taj Nasser,5 Gregory Parkhurst1,2 1Parkhurst NuVision LASIK Eye Surgery, San Antonio, TX, USA; 2Amarillo NuVision, Amarillo, TX, USA; 3Texas State University, San Marcos, TX, USA; 4Mason Eye Institute, University of Missouri, Columbia, MO, USA; 5Tylock Nasser Vision, Irvine, TX, USACorrespondence: Matthew Hirabayashi, Parkhurst NuVision LASIK Eye Surgery, 9725 Datapoint Dr Suite 106, San Antonio, TX, 78229, USA, Tel +1 314 578 2374, Email [email protected]: To evaluate the effect of lighting conditions on Implantable Collamer Lens (ICL) vault and anterior chamber angle measurements using the MS-39, and to determine whether vault variability correlates with average vault or ICL power.Methods: A retrospective analysis was performed on 100 eyes from 53 patients who underwent EVO or EVO Toric ICL implantation. Postoperative anterior segment imaging was conducted using the MS-39 device under scotopic, mesopic, and photopic lighting. Vault and anterior chamber angles were measured, with angle values derived from the mean of the nasal and temporal readings along the 180° axis. A Friedman and ANOVA test assessed changes in measurements across lighting conditions. Pearson and Spearman correlation was used to evaluate relationships between vault variability, mean vault, and ICL power.Results: Mean vault significantly decreased under photopic conditions (393.8 ± 165.6 μm) compared to mesopic (486.7 ± 185.5 μm) and scotopic (495.6 ± 187.7 μm) states (p < 0.0001). Angle measurements increased significantly under brighter lighting (p < 0.0001). Vault variability positively correlated with mean vault (ρ = 0.395, p < 0.0001), while ICL power showed a weak negative correlation (ρ = − 0.224, p = 0.025).Conclusion: ICL vault and anterior chamber angle measurements vary meaningfully with lighting conditions. Eyes with higher vaults exhibit greater variability, while lower vaults demonstrated less variability across lighting conditions. ICL power may have a small but weak influence on vault dynamics. These findings may help refine ICL sizing strategies and postoperative assessment protocols.Keywords: refractive surgery, vision correction, phakic IOLs, vault, sizing

Dove Medical Press (Taylor and Francis Group)
Openalex Percentile: Top 7%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.