3D Geometry Scanning and Structural Integrity Assessment to Advance Meniscus Allograft Transplantation

PURPOSE: Meniscal allograft transplantation can restore joint biomechanics and alleviate symptoms, but its clinical use is limited by the scarcity of size-matched, structurally intact grafts. Current two-dimensional sizing and subjective inspection in tissue banks fail to capture complex three-dimensional geometry and subtle surface defects, highlighting the need for an accurate, reliable, and practical solution for routine donor tissue evaluation. METHODS: We developed an integrated system combining optical 3D scanning with curvature-based analysis for 3D geometry capture and surface defect detection in meniscus allografts. System performance was validated in terms of scanner accuracy and tissue bank workflow feasibility. RESULTS: The system completes each scan within 2 versus ~ 60 min for micro-computed tomography (μCT). It demonstrated μCT-comparable accuracy (mean volume difference: 6.9%; surface deviation: 8.3%). Scanning through phosphate buffer saline (PBS)-immersed transparent bags yielded equivalent accuracy to scanning in air (mean volume difference: 7.2%; surface deviation: 12.5%). The workflow demonstrated high intra- and inter-operator reproducibility. Viability testing revealed PBS-preserved tissues maintained > 94% viability for 20 min, whereas air-exposed tissues dropped below 70% within 10 min. For defect assessment, curvature metrics reliably identified surface wear, longitudinal, and radial defects, with size measurements for wear and longitudinal tears showing equivalence (± 10% margin) to stereomicroscopy. CONCLUSION: This portable system enables accurate and rapid 3D scanning under tissue banking conditions and quantitative surface defect detection. It supports improved graft shape matching and surface defect screening, offering a practical and scalable solution for tissue banks and clinical settings, potentially extendable to other fibrocartilaginous and osteochondral tissues.

Authors

Institutions

Publication Details

Journal
Annals of Biomedical Engineering
Published
2026-05-01
DOI
https://doi.org/10.1007/s10439-026-04162-1
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D Geometry Scanning and Structural Integrity Assessment to Advance Meniscus Allograft Transplantation

Dustin Mueller, Shuchun Sun, Haiyang Ma, Jian Chen et al.
Annals of Biomedical Engineering
Knee injuries and reconstruction techniques
article

3D Geometry Scanning and Structural Integrity Assessment to Advance Meniscus Allograft Transplantation

Dustin Mueller, Shuchun Sun, Haiyang Ma, Jian Chen, Pan Ge, William Michael Pullen, William C Bridges, Hai Yao, Shangping Wang, Jichao Zhao
article en

Abstract

PURPOSE: Meniscal allograft transplantation can restore joint biomechanics and alleviate symptoms, but its clinical use is limited by the scarcity of size-matched, structurally intact grafts. Current two-dimensional sizing and subjective inspection in tissue banks fail to capture complex three-dimensional geometry and subtle surface defects, highlighting the need for an accurate, reliable, and practical solution for routine donor tissue evaluation. METHODS: We developed an integrated system combining optical 3D scanning with curvature-based analysis for 3D geometry capture and surface defect detection in meniscus allografts. System performance was validated in terms of scanner accuracy and tissue bank workflow feasibility. RESULTS: The system completes each scan within 2 versus ~ 60 min for micro-computed tomography (μCT). It demonstrated μCT-comparable accuracy (mean volume difference: 6.9%; surface deviation: 8.3%). Scanning through phosphate buffer saline (PBS)-immersed transparent bags yielded equivalent accuracy to scanning in air (mean volume difference: 7.2%; surface deviation: 12.5%). The workflow demonstrated high intra- and inter-operator reproducibility. Viability testing revealed PBS-preserved tissues maintained > 94% viability for 20 min, whereas air-exposed tissues dropped below 70% within 10 min. For defect assessment, curvature metrics reliably identified surface wear, longitudinal, and radial defects, with size measurements for wear and longitudinal tears showing equivalence (± 10% margin) to stereomicroscopy. CONCLUSION: This portable system enables accurate and rapid 3D scanning under tissue banking conditions and quantitative surface defect detection. It supports improved graft shape matching and surface defect screening, offering a practical and scalable solution for tissue banks and clinical settings, potentially extendable to other fibrocartilaginous and osteochondral tissues.

Annals of Biomedical Engineering
Medical University of South Carolina (US), Clemson University (US)
Clemson University, National Institutes of Health
Openalex Percentile: Top 13%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.