Quantitative assessment of the repeatability of PermaGel as a ballistic tissue simulant

The awareness of economic, environmental and ethical considerations centred on replication of human tissue have increased in recent years. This has driven the need to find repeatable products which can be re-used without detriment to datasets whilst providing economic benefit to research programmes and reducing the quantity of material disposed of at the end of the trials phase. This study is focussed on the ability of PermaGel to provide a repeatable medium for both survivability and lethality applications when re-used continuously. A baseline series of tests were undertaken using a single stage gas gun, with the material samples then undergoing a series of melt/recast cycles before being tested again to examine any differences in performance. The results show that a 30.40% difference in depth of penetration was observed post thermal cycling of the material, whilst a 5.36% increase in the maximum diameter of the temporary cavity was also observed. These results have raised concerns on PermaGel's ability to be re-used accurately and recommendations on its use provided to ensure data inaccuracy risk is minimised. The findings herein have confirmed the concerns raised within the literature, provided the research community with a single point of source data, and recommended areas for future work to ensure continued characterisation is undertaken.

Authors

Institutions

Publication Details

Journal
International Journal of Legal Medicine
Published
2026-05-01
DOI
https://doi.org/10.1007/s00414-026-03821-1
Primary Topic
Energetic Materials and Combustion
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative assessment of the repeatability of PermaGel as a ballistic tissue simulant

James Read, Richard Critchley, Rachael Hazael, Rupert Williams et al.
International Journal of Legal Medicine
Energetic Materials and Combustion
article

Quantitative assessment of the repeatability of PermaGel as a ballistic tissue simulant

James Read, Richard Critchley, Rachael Hazael, Rupert Williams, Samuel Yates
article en

Abstract

The awareness of economic, environmental and ethical considerations centred on replication of human tissue have increased in recent years. This has driven the need to find repeatable products which can be re-used without detriment to datasets whilst providing economic benefit to research programmes and reducing the quantity of material disposed of at the end of the trials phase. This study is focussed on the ability of PermaGel to provide a repeatable medium for both survivability and lethality applications when re-used continuously. A baseline series of tests were undertaken using a single stage gas gun, with the material samples then undergoing a series of melt/recast cycles before being tested again to examine any differences in performance. The results show that a 30.40% difference in depth of penetration was observed post thermal cycling of the material, whilst a 5.36% increase in the maximum diameter of the temporary cavity was also observed. These results have raised concerns on PermaGel's ability to be re-used accurately and recommendations on its use provided to ensure data inaccuracy risk is minimised. The findings herein have confirmed the concerns raised within the literature, provided the research community with a single point of source data, and recommended areas for future work to ensure continued characterisation is undertaken.

International Journal of Legal Medicine
Defence Academy of the United Kingdom (GB)
Openalex Percentile: Top 13%
Energetic Materials and Combustion
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantitative assessment of the repeatability of PermaGel as a ballistic tissue simulant — James Read, Richard Critchley, et al. · International Journal of Legal Medicine (2026) | TGRS Research Map | TGRS