The 2 PW/1 Hz laser system for laser-driven proton tumor therapy facility CLAPA- <i>II</i> : Compact laser plasma accelerator II

In this paper, we report the recent progress on the 2 PW/1 Hz laser system for laser-driven proton tumor therapy facility CLAPA-II [Kedong et al., Phys. Rev. Accel. Beams 23, 111302 (2020)], and the system is currently capable of outputting a maximum single-pulse laser energy of 71.9 J, a pulse width of 29 fs, and a peak power of 2.48 PW for high-power fs lasers. In terms of laser quality parameters, ps contrast is better than 1012, and ns contrast is 2 × 1010. In terms of laser stability, the horizontal and vertical angular pointing fluctuations over 500 shots were measured to be 1.04 and 0.797 μrad, respectively. The device has currently been deployed in laser acceleration experiments.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2026-05-01
DOI
https://doi.org/10.1063/5.0322895
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The 2 PW/1 Hz laser system for laser-driven proton tumor therapy facility CLAPA- II : Compact laser plasma accelerator II

Philippe Fichot, Alain Pellegrina, Olivier Chalus, Hailong Zhang et al.
Review of Scientific Instruments
Laser-Plasma Interactions and Diagnostics
article

The 2 PW/1 Hz laser system for laser-driven proton tumor therapy facility CLAPA- II : Compact laser plasma accelerator II

Philippe Fichot, Alain Pellegrina, Olivier Chalus, Hailong Zhang, G. Rey, Yanying Zhao, Vincent Leroux, Chang Liu, Minjian Wu, Xueqing Yan, Yixing Geng
article en

Abstract

In this paper, we report the recent progress on the 2 PW/1 Hz laser system for laser-driven proton tumor therapy facility CLAPA-II [Kedong et al., Phys. Rev. Accel. Beams 23, 111302 (2020)], and the system is currently capable of outputting a maximum single-pulse laser energy of 71.9 J, a pulse width of 29 fs, and a peak power of 2.48 PW for high-power fs lasers. In terms of laser quality parameters, ps contrast is better than 1012, and ns contrast is 2 × 1010. In terms of laser stability, the horizontal and vertical angular pointing fluctuations over 500 shots were measured to be 1.04 and 0.797 μrad, respectively. The device has currently been deployed in laser acceleration experiments.

Review of Scientific InstrumentsVol. 97(5)
Peking University (CN), Thales (Australia) (AU), State Key Laboratory of Nuclear Physics and Technology
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Beijing Municipal Science and Technology Commission, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 9%
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.