Effect of simulated bur radius compensation on full-contour CAD crown morphology and trueness across tooth types. An in- silico study

at the maximum radius. Conversely, surface area and roughness metrics showed a consistent upward trend. Geometric trueness deteriorated substantially with larger radii. While maximum localized deviations (H.D) peaked between the 0.75 mm and 1.00 mm settings, overall morphological deviation (RMSE) continued to climb, peaking at the 1.25 mm to 1.50 mm settings depending on the tooth type. Specifically, the RMSE for the central incisor rose from 0.049 at the minimal compensation to a peak of 0.184, indicating substantial volumetric and geometric distortion compared to the ideal baseline design. The selection of bur radius size directly dictates the morphological reliability of dental CAD. The data demonstrate that a minimal radius (0.10 mm) yields the highest trueness to the ideal baseline, whereas larger settings cause substantial volumetric reduction and geometric deviation, particularly in posterior teeth. To minimize anatomical discrepancies, digital laboratory workflows better to restrict bur radius compensation to the minimum technically feasible values, pending further validation in physical milling processes.

Authors

Institutions

Publication Details

Journal
The Saudi Dental Journal
Published
2026-04-30
DOI
https://doi.org/10.1007/s44445-026-00169-5
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of simulated bur radius compensation on full-contour CAD crown morphology and trueness across tooth types. An in- silico study

Nabeel Martani
The Saudi Dental Journal
Dental materials and restorations
article

Effect of simulated bur radius compensation on full-contour CAD crown morphology and trueness across tooth types. An in- silico study

Nabeel Martani
article en

Abstract

at the maximum radius. Conversely, surface area and roughness metrics showed a consistent upward trend. Geometric trueness deteriorated substantially with larger radii. While maximum localized deviations (H.D) peaked between the 0.75 mm and 1.00 mm settings, overall morphological deviation (RMSE) continued to climb, peaking at the 1.25 mm to 1.50 mm settings depending on the tooth type. Specifically, the RMSE for the central incisor rose from 0.049 at the minimal compensation to a peak of 0.184, indicating substantial volumetric and geometric distortion compared to the ideal baseline design. The selection of bur radius size directly dictates the morphological reliability of dental CAD. The data demonstrate that a minimal radius (0.10 mm) yields the highest trueness to the ideal baseline, whereas larger settings cause substantial volumetric reduction and geometric deviation, particularly in posterior teeth. To minimize anatomical discrepancies, digital laboratory workflows better to restrict bur radius compensation to the minimum technically feasible values, pending further validation in physical milling processes.

The Saudi Dental JournalVol. 38(5)
Hawler Medical University (IQ)
Openalex Percentile: Top 11%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.