The Galvanic Corrosion Behavior of ZCuAl10Fe5Ni5 Coupled with SAF2507 Duplex Stainless Steel in Seawater

In nuclear power, marine engineering, and other fields, a matching system composed of duplex steel and copper alloy is a common combination for rotating components in a seawater environment. However, this system is susceptible to galvanic corrosion that seriously threatens its service safety and service life, with ZCuAl10Fe5Ni5 being the main component corroded. Additionally, current corrosion research on this system has evident gaps. Specifically, the influence of area ratio on galvanic corrosion remains insufficiently understood, and the action mechanism of Cl− on the ZCuAl10Fe5Ni5-based corrosion product film in seawater, as well as the product evolution path, has not been fully revealed, which restricts the development of targeted protection technologies. This study explores the degradation mechanism of ZCuAl10Fe5Ni5 in a specific high-salinity environment (20,000 mg/L Cl−), characteristic of nuclear power plant service conditions. The results show that due to the significant electrode potential difference between the SAF2507 duplex steel and ZCuAl10Fe5Ni5 copper alloy, a stable galvanic couple is formed, with ZCuAl10Fe5Ni5 acting as the anode and undergoing dissolution corrosion. When the area ratio of ZCuAl10Fe5Ni5 (anode) to SAF2507 duplex steel (cathode) is 1:50, a significantly stronger galvanic effect is observed. The high concentration of Cl− in seawater can damage the surface of the ZCuAl10Fe5Ni5-based corrosion product film, leading to intensified local corrosion. The ZCuAl10Fe5Ni5-derived corrosion products have a layered structure mainly comprising a mixed system of Cu-Al-Mg oxides/hydroxides, and the corrosion process is accompanied by selective aluminum depletion corrosion. This study provides insight into the corrosion mechanism and key influencing factors of ZCuAl10Fe5Ni5 in the matching system, as well as a theoretical basis and technical support for the design of compatibility metal materials in a seawater environment and the control of corrosion in ZCuAl10Fe5Ni5.

Authors

Institutions

Publication Details

Journal
Metals
Published
2026-04-27
DOI
https://doi.org/10.3390/met16050473
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Galvanic Corrosion Behavior of ZCuAl10Fe5Ni5 Coupled with SAF2507 Duplex Stainless Steel in Seawater

Kewei Fang, Wanxiang Zhao, Pu Zhao, Mengmeng Zhu et al.
Metals
Corrosion Behavior and Inhibition
article

The Galvanic Corrosion Behavior of ZCuAl10Fe5Ni5 Coupled with SAF2507 Duplex Stainless Steel in Seawater

Kewei Fang, Wanxiang Zhao, Pu Zhao, Mengmeng Zhu, Jiachang Lu, Kunjie Luo, Yanxin Qiao, Hongqun Liu, Shuiyong Wang
article en

Abstract

In nuclear power, marine engineering, and other fields, a matching system composed of duplex steel and copper alloy is a common combination for rotating components in a seawater environment. However, this system is susceptible to galvanic corrosion that seriously threatens its service safety and service life, with ZCuAl10Fe5Ni5 being the main component corroded. Additionally, current corrosion research on this system has evident gaps. Specifically, the influence of area ratio on galvanic corrosion remains insufficiently understood, and the action mechanism of Cl− on the ZCuAl10Fe5Ni5-based corrosion product film in seawater, as well as the product evolution path, has not been fully revealed, which restricts the development of targeted protection technologies. This study explores the degradation mechanism of ZCuAl10Fe5Ni5 in a specific high-salinity environment (20,000 mg/L Cl−), characteristic of nuclear power plant service conditions. The results show that due to the significant electrode potential difference between the SAF2507 duplex steel and ZCuAl10Fe5Ni5 copper alloy, a stable galvanic couple is formed, with ZCuAl10Fe5Ni5 acting as the anode and undergoing dissolution corrosion. When the area ratio of ZCuAl10Fe5Ni5 (anode) to SAF2507 duplex steel (cathode) is 1:50, a significantly stronger galvanic effect is observed. The high concentration of Cl− in seawater can damage the surface of the ZCuAl10Fe5Ni5-based corrosion product film, leading to intensified local corrosion. The ZCuAl10Fe5Ni5-derived corrosion products have a layered structure mainly comprising a mixed system of Cu-Al-Mg oxides/hydroxides, and the corrosion process is accompanied by selective aluminum depletion corrosion. This study provides insight into the corrosion mechanism and key influencing factors of ZCuAl10Fe5Ni5 in the matching system, as well as a theoretical basis and technical support for the design of compatibility metal materials in a seawater environment and the control of corrosion in ZCuAl10Fe5Ni5.

MetalsVol. 16(5)
Jiangsu University of Science and Technology (CN), Suzhou Research Institute (CN)
Life below water
Openalex Percentile: Top 9%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.