Novel technique for fixating the plate of the Ahmed valve to the sclera using a single-flanged prolene suture

Abstract: PURPOSE: The purpose of this study was to evaluate a novel technique for fixating the plate of the Ahmed glaucoma valve (AGV) to the sclera using a single-flanged prolene suture. METHODS: This study involved 40 eyes of 40 patients diagnosed with different types of primary and secondary open-angle glaucoma who had undergone AGV implantation with plate fixation using a single-flanged prolene suture technique. The clinical data regarding the duration of surgery, intra- and postoperative complications, best-corrected visual acuity, intraocular pressure (IOP), and the number of IOP-lowering drugs were retrieved. RESULTS: The mean age of patients was 50.3 ± 11.8 years. The average follow-up period was 5.3 ± 1.7 months. The mean duration of surgery was 25.3 ± 6.7 min. Preoperatively, all patients were on full antiglaucoma medication with a mean IOP of 32.4 ± 6.3 mmHg. Significantly lower postoperative IOP than at baseline at all visits ( P < 0.05) was found. Postoperative IOP at 1 week, 1 month, and 3 months were 11.8 ± 3.6, 14.2 ± 4.2, and 15.3 ± 2.6 mmHg, respectively ( P = 0.002). In this study, complete success occurred in 30 (75%) cases, while qualified success was encountered in the remaining 10 (25%) cases with stable IOP 6-21 mmHg on a fixed dorzolamide–timolol glaucoma combination. The number of IOP-lowering medications was 1.8 ± 0.3 postoperative compared to 3.8 ± 0.4 preoperative. No cases of exposed or migrated tubes or plates were reported in this study. No major post operative complications in the form of tube touch to the iris, tube occlusion, shallow anterior chamber, hypotony, or choroid effusion occurred in this study. CONCLUSION: This novel technique of fixating the plate of AGV to the sclera using a single-flanged prolene suture is an efficient, safe, and reproducible technique that provides excellent stability without complications of free plate techniques and at the same time minimizes risks of conventional old valve plate fixation techniques.

Authors

Institutions

Publication Details

Journal
Saudi Journal of Ophthalmology
Published
2026-04-24
DOI
https://doi.org/10.4103/sjopt.sjopt_335_25
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel technique for fixating the plate of the Ahmed valve to the sclera using a single-flanged prolene suture

Mohammed K. Aly, Husam M. Faramawi, Mohamed M. Eldaly, Mohammed A. Al-Naimy et al.
Saudi Journal of Ophthalmology
Glaucoma and retinal disorders
article

Novel technique for fixating the plate of the Ahmed valve to the sclera using a single-flanged prolene suture

Mohammed K. Aly, Husam M. Faramawi, Mohamed M. Eldaly, Mohammed A. Al-Naimy, Ahmed Samir
article en

Abstract

Abstract: PURPOSE: The purpose of this study was to evaluate a novel technique for fixating the plate of the Ahmed glaucoma valve (AGV) to the sclera using a single-flanged prolene suture. METHODS: This study involved 40 eyes of 40 patients diagnosed with different types of primary and secondary open-angle glaucoma who had undergone AGV implantation with plate fixation using a single-flanged prolene suture technique. The clinical data regarding the duration of surgery, intra- and postoperative complications, best-corrected visual acuity, intraocular pressure (IOP), and the number of IOP-lowering drugs were retrieved. RESULTS: The mean age of patients was 50.3 ± 11.8 years. The average follow-up period was 5.3 ± 1.7 months. The mean duration of surgery was 25.3 ± 6.7 min. Preoperatively, all patients were on full antiglaucoma medication with a mean IOP of 32.4 ± 6.3 mmHg. Significantly lower postoperative IOP than at baseline at all visits ( P < 0.05) was found. Postoperative IOP at 1 week, 1 month, and 3 months were 11.8 ± 3.6, 14.2 ± 4.2, and 15.3 ± 2.6 mmHg, respectively ( P = 0.002). In this study, complete success occurred in 30 (75%) cases, while qualified success was encountered in the remaining 10 (25%) cases with stable IOP 6-21 mmHg on a fixed dorzolamide–timolol glaucoma combination. The number of IOP-lowering medications was 1.8 ± 0.3 postoperative compared to 3.8 ± 0.4 preoperative. No cases of exposed or migrated tubes or plates were reported in this study. No major post operative complications in the form of tube touch to the iris, tube occlusion, shallow anterior chamber, hypotony, or choroid effusion occurred in this study. CONCLUSION: This novel technique of fixating the plate of AGV to the sclera using a single-flanged prolene suture is an efficient, safe, and reproducible technique that provides excellent stability without complications of free plate techniques and at the same time minimizes risks of conventional old valve plate fixation techniques.

Saudi Journal of Ophthalmology
Zagazig University (EG), Magrabi Hospitals and Centers (SA)
Openalex Percentile: Top 4%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.