Precise X-ray Visualization by Double Network Polymeric Gel

Gel dosimeters are an important tool for radiotherapy dose verification due to their tissue equivalence, but their widespread use has been constrained by complex readout processes, limited spatial resolution, and instability of postirradiation. Herein, we use radiation-induced expansion, yielding a dose-dependent and continuous redshift in its structural color. This double network dosimeter can detect X-rays with a maximum sensitivity of 35.8 nm/Gy and spatial resolution exceeding 50 μm in the range of 0-10 Gy. Moreover, it exhibits excellent stability against environmental factors, including UV irradiation, and its dosimetric information (spectral reflection peak position) remains unchanged after 10 drying-wetting cycles. In addition, it is feasible for three-dimensional (3D) printing of complex shapes, a capability that is inaccessible to existing gel dosimeters. Therefore, the present study provides spatially precise gel dosimeters for advanced radiotherapy verification.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2026-04-30
DOI
https://doi.org/10.1021/acsami.6c03364
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precise X-ray Visualization by Double Network Polymeric Gel

Yinyong Ao, Lei Yu, Pucheng Wang, Zhihao Wang et al.
ACS Applied Materials & Interfaces
Advanced Radiotherapy Techniques
article

Precise X-ray Visualization by Double Network Polymeric Gel

Yinyong Ao, Lei Yu, Pucheng Wang, Zhihao Wang, Jun Ma, Qinqin Xiang
article en

Abstract

Gel dosimeters are an important tool for radiotherapy dose verification due to their tissue equivalence, but their widespread use has been constrained by complex readout processes, limited spatial resolution, and instability of postirradiation. Herein, we use radiation-induced expansion, yielding a dose-dependent and continuous redshift in its structural color. This double network dosimeter can detect X-rays with a maximum sensitivity of 35.8 nm/Gy and spatial resolution exceeding 50 μm in the range of 0-10 Gy. Moreover, it exhibits excellent stability against environmental factors, including UV irradiation, and its dosimetric information (spectral reflection peak position) remains unchanged after 10 drying-wetting cycles. In addition, it is feasible for three-dimensional (3D) printing of complex shapes, a capability that is inaccessible to existing gel dosimeters. Therefore, the present study provides spatially precise gel dosimeters for advanced radiotherapy verification.

ACS Applied Materials & Interfaces
University of Science and Technology of China (CN), China Academy of Engineering Physics (CN), NIST Center for Neutron Research (US), PRG S&Tech (South Korea)
National Natural Science Foundation of China, Beijing National Laboratory for Molecular Sciences
Life in Land
Openalex Percentile: Top 8%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.