RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF CELECOXIB AND METFORMIN HYDROCHLORIDE IN SYNTHETIC MIXTURE

The Objective of this study was to develop and validate precise, accurate, and rapid RP-HPLC method for the simultaneous estimation of Celecoxib and Metformin Hydrochloride in a synthetic mixture as per ICH guidelines. In RP-HPLC method, the chromatographic system was equipped with Kromstar C18 (250 mm × 4.6 mm internal diameter × 5 μm particle size). and UV detector set at 231 nm and a Mobile Phase consisting of Phosphate buffer: Methanol: Acetonitrile (pH: 2.8 adjusted with 10% Ortho phosphoric acid) (52:28:20 % v/v/v) was used at a flow rate 1 ml/min. The retention time was found to be approximately 2.5 min for Metformin and 5.8 min for Celecoxib, ensuring proper separation of both drugs. The various analytical parameters, including specificity, linearity, LOD, LOQ, precision, accuracy, and robustness, were determined ICH guidelines. RP-HPLC method showed good linearity, precision, and accuracy with correlation coefficients close to 1. Recovery studies were within acceptable limits. Low LOD and LOQ values indicated high sensitivity. Percentage assay values were close to 100%, confirming the reliability of the developed method. The developed RP-HPLC method was found to be specific, accurate, precise, robust, economical, and reproducible. This method is suitable for routine quality control analysis of Celecoxib and Metformin Hydrochloride in synthetic mixtures.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-05-01
DOI
https://doi.org/10.5281/zenodo.19885306
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF CELECOXIB AND METFORMIN HYDROCHLORIDE IN SYNTHETIC MIXTURE

Prachi Vihol1, Divyakant Patel2, Janki Patel3*
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF CELECOXIB AND METFORMIN HYDROCHLORIDE IN SYNTHETIC MIXTURE

Prachi Vihol1, Divyakant Patel2, Janki Patel3*
article en

Abstract

The Objective of this study was to develop and validate precise, accurate, and rapid RP-HPLC method for the simultaneous estimation of Celecoxib and Metformin Hydrochloride in a synthetic mixture as per ICH guidelines. In RP-HPLC method, the chromatographic system was equipped with Kromstar C18 (250 mm × 4.6 mm internal diameter × 5 μm particle size). and UV detector set at 231 nm and a Mobile Phase consisting of Phosphate buffer: Methanol: Acetonitrile (pH: 2.8 adjusted with 10% Ortho phosphoric acid) (52:28:20 % v/v/v) was used at a flow rate 1 ml/min. The retention time was found to be approximately 2.5 min for Metformin and 5.8 min for Celecoxib, ensuring proper separation of both drugs. The various analytical parameters, including specificity, linearity, LOD, LOQ, precision, accuracy, and robustness, were determined ICH guidelines. RP-HPLC method showed good linearity, precision, and accuracy with correlation coefficients close to 1. Recovery studies were within acceptable limits. Low LOD and LOQ values indicated high sensitivity. Percentage assay values were close to 100%, confirming the reliability of the developed method. The developed RP-HPLC method was found to be specific, accurate, precise, robust, economical, and reproducible. This method is suitable for routine quality control analysis of Celecoxib and Metformin Hydrochloride in synthetic mixtures.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 6%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF CELECOXIB AND METFORMIN HYDROCHLORIDE IN SYNTHETIC MIXTURE — Prachi Vihol1, Divyakant Patel2, Janki Patel3* · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS