Structural Optimization and Thermal Performance Analysis of a Bio-Inspired Leaf-Vein Liquid Cooling System for Lithium-Ion Batteries: A Case Study of Agricultural Electric Forklifts

To improve the thermal management performance of lithium-ion batteries under high discharge rates and complex operating conditions, a bidirectional parallel bionic flow-channel cooling plate is proposed, with agricultural electric forklifts taken as the representative application background. Numerical simulations were first carried out to compare the heat dissipation characteristics of a conventional leaf-vein flow channel, a unidirectional parallel bionic leaf-vein flow channel, and a bidirectional parallel bionic leaf-vein flow channel. On this basis, the effects of structural parameters on the thermal performance of the liquid cooling plate were systematically investigated using a single-factor analysis method. Furthermore, an orthogonal optimization experiment was performed for four major influencing factors. The results indicate that the unidirectional parallel bionic leaf-vein flow channel improved the coolant coverage relative to the conventional leaf-vein structure; however, owing to the one-sided coolant supply mode, a high-temperature retention zone tended to appear at the end of the channel. In contrast, the bidirectional parallel bionic design effectively alleviated this problem by supplying coolant synchronously from both sides. The main channel width, branch channel width, total channel height, and branch inclination angle were identified as the dominant factors affecting heat dissipation performance. Under the optimized structure and operating condition, the maximum temperature and temperature difference of the battery module were reduced to 29.85 °C and 4.48 °C, respectively.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-04-27
DOI
https://doi.org/10.3390/app16094277
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Optimization and Thermal Performance Analysis of a Bio-Inspired Leaf-Vein Liquid Cooling System for Lithium-Ion Batteries: A Case Study of Agricultural Electric Forklifts

Yuzheng Wu, Bing Fang, Dapeng Ye, Zinan Ye
Applied Sciences
Advanced Battery Technologies Research
article

Structural Optimization and Thermal Performance Analysis of a Bio-Inspired Leaf-Vein Liquid Cooling System for Lithium-Ion Batteries: A Case Study of Agricultural Electric Forklifts

Yuzheng Wu, Bing Fang, Dapeng Ye, Zinan Ye
article en

Abstract

To improve the thermal management performance of lithium-ion batteries under high discharge rates and complex operating conditions, a bidirectional parallel bionic flow-channel cooling plate is proposed, with agricultural electric forklifts taken as the representative application background. Numerical simulations were first carried out to compare the heat dissipation characteristics of a conventional leaf-vein flow channel, a unidirectional parallel bionic leaf-vein flow channel, and a bidirectional parallel bionic leaf-vein flow channel. On this basis, the effects of structural parameters on the thermal performance of the liquid cooling plate were systematically investigated using a single-factor analysis method. Furthermore, an orthogonal optimization experiment was performed for four major influencing factors. The results indicate that the unidirectional parallel bionic leaf-vein flow channel improved the coolant coverage relative to the conventional leaf-vein structure; however, owing to the one-sided coolant supply mode, a high-temperature retention zone tended to appear at the end of the channel. In contrast, the bidirectional parallel bionic design effectively alleviated this problem by supplying coolant synchronously from both sides. The main channel width, branch channel width, total channel height, and branch inclination angle were identified as the dominant factors affecting heat dissipation performance. Under the optimized structure and operating condition, the maximum temperature and temperature difference of the battery module were reduced to 29.85 °C and 4.48 °C, respectively.

Applied SciencesVol. 16(9)
Fujian Academy of Agricultural Sciences (CN), Fujian Agriculture and Forestry University (CN), Fujian University of Technology (CN)
Fujian Provincial Department of Science and Technology
Zero hunger
Openalex Percentile: Top 7%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.