A ROBUST ICP-MS METHOD FOR MULTI-ELEMENT TRACE METAL ANALYSIS IN HUMAN WHOLE BLOOD

Monitoring trace and toxic elements in blood is essential for clinical toxicology, occupational exposure assessment and biomonitoring assessment, a rapid sensitive and robust method developed for the simultaneous quantification of Arsenic(As), Lead(Pb), Cadmium(Cd), Manganese (Mn), Chromium (Cr), Cobalt (Co), and Thallium (Tl) in human blood. Whole blood samples were prepared using a simple dilution protocol with trace metal free nitric acid, tubes and selected internal standard to minimize matrix effect and maintain analyte stability. Instrument parameters such as RF power, nebulizer gas flow, dwell time, and collision/reaction cell conditions were systematically optimized to enhance sensitivity and reduce spectral interferences. Quantification was performed using multi-point external calibration with internal standard correction. The method demonstrated excellent linearity for all analytes with correlation coefficients (r2>0.99) across clinically relevant concentration range. The developed ICP-MS method is a reliable and high-throughput approach for simultaneous multi-element blood analysis. Its sensitivity, robustness and simplified sample preparation make it highly suitable for routine clinical diagnostics, toxic metal screening, and population biomonitoring studies.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-05-01
DOI
https://doi.org/10.5281/zenodo.19885445
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A ROBUST ICP-MS METHOD FOR MULTI-ELEMENT TRACE METAL ANALYSIS IN HUMAN WHOLE BLOOD

Rohit Saxena*1, Nimmi Kansal1, Mah Alam1, Murugesan Suresh2
Zenodo (CERN European Organization for Nuclear Research)
Analytical chemistry methods development
article

A ROBUST ICP-MS METHOD FOR MULTI-ELEMENT TRACE METAL ANALYSIS IN HUMAN WHOLE BLOOD

Rohit Saxena*1, Nimmi Kansal1, Mah Alam1, Murugesan Suresh2
article en

Abstract

Monitoring trace and toxic elements in blood is essential for clinical toxicology, occupational exposure assessment and biomonitoring assessment, a rapid sensitive and robust method developed for the simultaneous quantification of Arsenic(As), Lead(Pb), Cadmium(Cd), Manganese (Mn), Chromium (Cr), Cobalt (Co), and Thallium (Tl) in human blood. Whole blood samples were prepared using a simple dilution protocol with trace metal free nitric acid, tubes and selected internal standard to minimize matrix effect and maintain analyte stability. Instrument parameters such as RF power, nebulizer gas flow, dwell time, and collision/reaction cell conditions were systematically optimized to enhance sensitivity and reduce spectral interferences. Quantification was performed using multi-point external calibration with internal standard correction. The method demonstrated excellent linearity for all analytes with correlation coefficients (r2>0.99) across clinically relevant concentration range. The developed ICP-MS method is a reliable and high-throughput approach for simultaneous multi-element blood analysis. Its sensitivity, robustness and simplified sample preparation make it highly suitable for routine clinical diagnostics, toxic metal screening, and population biomonitoring studies.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 7%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A ROBUST ICP-MS METHOD FOR MULTI-ELEMENT TRACE METAL ANALYSIS IN HUMAN WHOLE BLOOD — Rohit Saxena*1, Nimmi Kansal1, Mah Alam1, Murugesan Suresh2 · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS