Which Is the Most Suitable Ventilation System for Residential Buildings? Case Study in Northern Spain

This study evaluates simple exhaust, relative humidity-controlled and heat recovery ventilation systems in northern Spain (SEV, RHCV, HRV systems) through simulations of indoor air quality (IAQ), energy, and exergy performance. The IAQ analysis reveals poor performance of the RHCV system for indoor source pollutants such as formaldehyde (HCHO) and total volatile organic compounds (TVOC). The HRV system demonstrates superior energy efficiency, with 30% lower primary energy consumption than the SEV system, though it is necessary to evaluate whether the heat recovered compensates for the increased fan energy consumption. This condition is evaluated by defining an outdoor air temperature limit value. The exergy analysis shows the HRV system requires 30% less primary exergy than the SEV system despite higher system demand. While HRV emerges as the optimal solution for balancing IAQ and energy performance, the findings highlight that source control remains necessary to effectively manage HCHO and TVOC concentrations. The research provides guidance for selecting ventilation systems that minimize pollutant exposure while optimizing energy resources.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-04-27
DOI
https://doi.org/10.3390/su18094309
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Which Is the Most Suitable Ventilation System for Residential Buildings? Case Study in Northern Spain

Zaloa Azkorra-Larrinaga, Iñaki Gómez-Arriaran, Joseba Gainza-Barrencua, Moises Odriozola-Maritorena et al.
Sustainability
Indoor Air Quality and Microbial Exposure
article

Which Is the Most Suitable Ventilation System for Residential Buildings? Case Study in Northern Spain

Zaloa Azkorra-Larrinaga, Iñaki Gómez-Arriaran, Joseba Gainza-Barrencua, Moises Odriozola-Maritorena, Ana Picallo-Perez
article en

Abstract

This study evaluates simple exhaust, relative humidity-controlled and heat recovery ventilation systems in northern Spain (SEV, RHCV, HRV systems) through simulations of indoor air quality (IAQ), energy, and exergy performance. The IAQ analysis reveals poor performance of the RHCV system for indoor source pollutants such as formaldehyde (HCHO) and total volatile organic compounds (TVOC). The HRV system demonstrates superior energy efficiency, with 30% lower primary energy consumption than the SEV system, though it is necessary to evaluate whether the heat recovered compensates for the increased fan energy consumption. This condition is evaluated by defining an outdoor air temperature limit value. The exergy analysis shows the HRV system requires 30% less primary exergy than the SEV system despite higher system demand. While HRV emerges as the optimal solution for balancing IAQ and energy performance, the findings highlight that source control remains necessary to effectively manage HCHO and TVOC concentrations. The research provides guidance for selecting ventilation systems that minimize pollutant exposure while optimizing energy resources.

SustainabilityVol. 18(9)
University of the Basque Country (ES), Donostia International Physics Center (ES)
European Commission, Interreg
Affordable and clean energy
Openalex Percentile: Top 7%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.