Leak Location in CCUS Wellbores Using Autocorrelation Delay Features: Method and Field Application

Stable leak localization in CCUS injection wellbores remains difficult under strong background noise. This study proposes a leak localization method based on autocorrelation time delay features of leakage acoustic signals. Considering the generation of confined leakage noise and its waveguide propagation in the wellbore, a time delay relationship between the direct acoustic component and the bottom-reflected echo is established, and an integrated workflow is developed for signal preprocessing, normalized autocorrelation analysis, feature extraction, and location inversion. Experimental results show that the dominant autocorrelation time delay feature remains stable under varying leakage conditions, while leak position changes produce distinguishable peak–valley patterns. The proposed method achieves high localization accuracy, with absolute errors of 0.018–0.046 m and relative errors of 0.76–1.93% under the tested conditions. A field application in a CO2 injection well further demonstrates its practical feasibility. Overall, the method provides a stable and effective approach for leak localization in CCUS injection wellbores and shows potential for engineering applications in noisy environments.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-04-26
DOI
https://doi.org/10.3390/en19092091
Primary Topic
Drilling and Well Engineering
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Leak Location in CCUS Wellbores Using Autocorrelation Delay Features: Method and Field Application

Xiang Bai, Qijia Zhou, Liwei Zhang, Zhiming Jiang et al.
Energies
Drilling and Well Engineering
article

Leak Location in CCUS Wellbores Using Autocorrelation Delay Features: Method and Field Application

Xiang Bai, Qijia Zhou, Liwei Zhang, Zhiming Jiang, Xiaoyi Zhai, Jianchun Fan, Min Li
article en

Abstract

Stable leak localization in CCUS injection wellbores remains difficult under strong background noise. This study proposes a leak localization method based on autocorrelation time delay features of leakage acoustic signals. Considering the generation of confined leakage noise and its waveguide propagation in the wellbore, a time delay relationship between the direct acoustic component and the bottom-reflected echo is established, and an integrated workflow is developed for signal preprocessing, normalized autocorrelation analysis, feature extraction, and location inversion. Experimental results show that the dominant autocorrelation time delay feature remains stable under varying leakage conditions, while leak position changes produce distinguishable peak–valley patterns. The proposed method achieves high localization accuracy, with absolute errors of 0.018–0.046 m and relative errors of 0.76–1.93% under the tested conditions. A field application in a CO2 injection well further demonstrates its practical feasibility. Overall, the method provides a stable and effective approach for leak localization in CCUS injection wellbores and shows potential for engineering applications in noisy environments.

EnergiesVol. 19(9)
China University of Petroleum, Beijing (CN), Karamay Central Hospital of Xinjiang (CN), China National Petroleum Corporation (China) (CN)
China University of Petroleum, Beijing, PetroChina Company Limited, Xinjiang Oilfield Company
Openalex Percentile: Top 6%
Drilling and Well Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.