Trabecular Meshwork Thickness Measured by Swept-Source AS-OCT as a Predictor of Surgical Outcomes After Trabecular Micro-Bypass Stent Implantation

Background: Although minimally invasive glaucoma surgery (MIGS), including trabecular micro-bypass stent implantation, is safe, its surgical outcomes remain variable, with limited reliable success predictors. We evaluated whether preoperative trabecular meshwork (TM) thickness is associated with surgical outcomes after iStent inject® W implantation. Methods: Patients with open-angle glaucoma (n = 28) who underwent iStent inject® W implantation were included. Preoperative AS-SS-OCT was used to measure TM thickness and conventional angle parameters, including angle opening distance, angle recess area, trabecular–iris space area, and trabecular–iris angle. Surgical success was IOP ≤ 15 mmHg with ≥25% reduction or final IOP ≤ 12 mmHg under specified conditions. Logistic regression analyses were performed to identify factors associated with surgical outcomes. Results: At 12 months, 22 eyes (78.6%) achieved surgical success. Mean TM thickness was significantly greater in the unsuccessful than in the successful group (250.62 ± 32.05 μm vs. 180.75 ± 30.61 μm, p = 0.001), with similar findings for nasal and temporal TM thickness. Conventional angle parameters were not associated with surgical outcomes. In univariable analysis, both mean and nasal TM thickness were significantly associated with an increased risk of failure (per 10 μm increase; mean TM: OR = 2.77, 95% CI = 1.12–6.86, p = 0.027; nasal TM: OR = 1.64, 95% CI = 1.04–2.58, p = 0.034). Conclusions: Increased preoperative mean and nasal TM thickness was significantly associated with surgical failure following iStent inject® W implantation. TM’s microstructural properties are more relevant than angular configuration in determining MIGS outcomes. Preoperative assessment of TM thickness using AS-SS-OCT may serve as a useful imaging biomarker for optimizing patient selection.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-04-27
DOI
https://doi.org/10.3390/jcm15093341
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trabecular Meshwork Thickness Measured by Swept-Source AS-OCT as a Predictor of Surgical Outcomes After Trabecular Micro-Bypass Stent Implantation

S K Lee, J S Lee, JiEun Lee, Heejin Yoon et al.
Journal of Clinical Medicine
Glaucoma and retinal disorders
article

Trabecular Meshwork Thickness Measured by Swept-Source AS-OCT as a Predictor of Surgical Outcomes After Trabecular Micro-Bypass Stent Implantation

S K Lee, J S Lee, JiEun Lee, Heejin Yoon, Sangwoo Moon, Su Jin Kim
article en

Abstract

Background: Although minimally invasive glaucoma surgery (MIGS), including trabecular micro-bypass stent implantation, is safe, its surgical outcomes remain variable, with limited reliable success predictors. We evaluated whether preoperative trabecular meshwork (TM) thickness is associated with surgical outcomes after iStent inject® W implantation. Methods: Patients with open-angle glaucoma (n = 28) who underwent iStent inject® W implantation were included. Preoperative AS-SS-OCT was used to measure TM thickness and conventional angle parameters, including angle opening distance, angle recess area, trabecular–iris space area, and trabecular–iris angle. Surgical success was IOP ≤ 15 mmHg with ≥25% reduction or final IOP ≤ 12 mmHg under specified conditions. Logistic regression analyses were performed to identify factors associated with surgical outcomes. Results: At 12 months, 22 eyes (78.6%) achieved surgical success. Mean TM thickness was significantly greater in the unsuccessful than in the successful group (250.62 ± 32.05 μm vs. 180.75 ± 30.61 μm, p = 0.001), with similar findings for nasal and temporal TM thickness. Conventional angle parameters were not associated with surgical outcomes. In univariable analysis, both mean and nasal TM thickness were significantly associated with an increased risk of failure (per 10 μm increase; mean TM: OR = 2.77, 95% CI = 1.12–6.86, p = 0.027; nasal TM: OR = 1.64, 95% CI = 1.04–2.58, p = 0.034). Conclusions: Increased preoperative mean and nasal TM thickness was significantly associated with surgical failure following iStent inject® W implantation. TM’s microstructural properties are more relevant than angular configuration in determining MIGS outcomes. Preoperative assessment of TM thickness using AS-SS-OCT may serve as a useful imaging biomarker for optimizing patient selection.

Journal of Clinical MedicineVol. 15(9)
Pusan National University Hospital (KR), Pusan National University Yangsan Hospital (KR)
Pusan National University
Openalex Percentile: Top 4%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.