Evaluation of the Eosin‐5′‐Maleimide Flow Cytometry Test for the Diagnosis of Hereditary Spherocytosis

INTRODUCTION: Hereditary spherocytosis (HS) is a congenital hemolytic anemia caused by erythrocyte membrane protein defects. While the eosin-5'-maleimide (EMA) binding test by flow cytometry is the established first-line assay, this study evaluates its optimal cut-offs and performance within a large, real-world cohort. METHODS: We retrospectively analyzed 181 consecutive samples (2017-2024) with suspected HS. EMA binding was performed by flow cytometry using conventional and standardized protocols; the latter (implemented in 2023) utilized fixed erythrocyte counts and FL1 bead calibration. Accuracy was assessed against a composite clinical-laboratory reference standard. ROC analysis determined sensitivity, specificity, likelihood ratios, and AUC. RESULTS: HS was confirmed in 50/181 cases (27.6%). EMA fluorescence reduction was significantly greater in HS (median 23.0%) than in non-HS samples (9.0%). The optimal cut-off (16.5%) yielded 96.0% sensitivity, 96.9% specificity, and AUC = 0.990 (95% CI 0.979-0.998). Both conventional and standardized protocols showed equivalent accuracy (AUC 0.988 vs. 0.992). False positives were mainly associated with severe microcytosis or autoimmune hemolytic anemia. CONCLUSIONS: In a consecutive, real-world cohort of patients with suspected hereditary spherocytosis referred to a single reference laboratory receiving samples from across the country, the EMA test demonstrated high diagnostic accuracy consistent with previous reports. Importantly, implementation of a standardized protocol resolved reproducibility issues in fluorescence intensity measurement without compromising diagnostic performance, supporting its robustness and applicability in routine clinical laboratories.

Authors

Institutions

Publication Details

Journal
European Journal Of Haematology
Published
2026-04-27
DOI
https://doi.org/10.1111/ejh.70204
Primary Topic
Erythrocyte Function and Pathophysiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Eosin‐5′‐Maleimide Flow Cytometry Test for the Diagnosis of Hereditary Spherocytosis

Pablo Adrian Biaggioni, Alejandro Ceferino López Romero
European Journal Of Haematology
Erythrocyte Function and Pathophysiology
article

Evaluation of the Eosin‐5′‐Maleimide Flow Cytometry Test for the Diagnosis of Hereditary Spherocytosis

Pablo Adrian Biaggioni, Alejandro Ceferino López Romero
article en

Abstract

INTRODUCTION: Hereditary spherocytosis (HS) is a congenital hemolytic anemia caused by erythrocyte membrane protein defects. While the eosin-5'-maleimide (EMA) binding test by flow cytometry is the established first-line assay, this study evaluates its optimal cut-offs and performance within a large, real-world cohort. METHODS: We retrospectively analyzed 181 consecutive samples (2017-2024) with suspected HS. EMA binding was performed by flow cytometry using conventional and standardized protocols; the latter (implemented in 2023) utilized fixed erythrocyte counts and FL1 bead calibration. Accuracy was assessed against a composite clinical-laboratory reference standard. ROC analysis determined sensitivity, specificity, likelihood ratios, and AUC. RESULTS: HS was confirmed in 50/181 cases (27.6%). EMA fluorescence reduction was significantly greater in HS (median 23.0%) than in non-HS samples (9.0%). The optimal cut-off (16.5%) yielded 96.0% sensitivity, 96.9% specificity, and AUC = 0.990 (95% CI 0.979-0.998). Both conventional and standardized protocols showed equivalent accuracy (AUC 0.988 vs. 0.992). False positives were mainly associated with severe microcytosis or autoimmune hemolytic anemia. CONCLUSIONS: In a consecutive, real-world cohort of patients with suspected hereditary spherocytosis referred to a single reference laboratory receiving samples from across the country, the EMA test demonstrated high diagnostic accuracy consistent with previous reports. Importantly, implementation of a standardized protocol resolved reproducibility issues in fluorescence intensity measurement without compromising diagnostic performance, supporting its robustness and applicability in routine clinical laboratories.

European Journal Of Haematology
Centro Científico Tecnológico - Bahía Blanca (AR)
Gender equality
Openalex Percentile: Top 5%
Erythrocyte Function and Pathophysiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.