A Practical Weakly Supervised Framework for Dose-Up Translation of Low-Enhanced CT Under Clinical Acquisition Variability

Low-dose contrast-enhanced computed tomography (CT) is widely used to reduce contrast-induced toxicity, but reduced iodine concentration and inconsistent acquisition conditions often produce uneven contrast attenuation and spatial misalignment between scans. In this context, we define dose-up translation as the computational process of synthetically enhancing low-dose contrast images to approximate the visual and diagnostic quality of full-dose acquisitions. These factors limit the effective use of routinely acquired imaging data for dose-up translation, particularly in veterinary abdominal CT where respiratory motion and postural variability further degrade anatomical correspondence. We present a weakly aligned enhancement framework designed to operate under spatial misalignment and limited paired data. Registration-based pseudo-references are constructed using a hybrid strategy that combines deformable anatomical alignment with feature-level correspondence. Dose-up translation is performed using structure-preserving translation with multi-scale consistency and edge-aware regularization to maintain anatomical boundaries. To address limited low-dose datasets, a two-stage knowledge transfer strategy transfers anatomical and contrast priors from abundant pre-contrast data. Quantitative evaluation demonstrated region-level contrast-to-noise ratio improvements of up to 31.5% (e.g., from 5.55 to 8.38 in the caudal vena cava (CVC), P < 0.05) compared with baseline enhancement methods across 1171 test slices. Experiments demonstrate consistent improvements in structural fidelity, distributional realism, and region-level vascular conspicuity compared with paired, unpaired, and synthetic-pairing baselines. These findings suggest that the dose-up translation of low-enhanced CT is better formulated as a weakly aligned domain adaptation problem rather than a strictly paired reconstruction task, enabling practical image translation under realistic clinical acquisition variability.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2026-04-27
DOI
https://doi.org/10.3390/jimaging12050190
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Practical Weakly Supervised Framework for Dose-Up Translation of Low-Enhanced CT Under Clinical Acquisition Variability

Hyun Gyu Lee, Jong Bub Lee, Se Hwan Lim, Yu Jin Jung et al.
Journal of Imaging
Advanced X-ray and CT Imaging
article

A Practical Weakly Supervised Framework for Dose-Up Translation of Low-Enhanced CT Under Clinical Acquisition Variability

Hyun Gyu Lee, Jong Bub Lee, Se Hwan Lim, Yu Jin Jung, Jae Hwan Kim
article en

Abstract

Low-dose contrast-enhanced computed tomography (CT) is widely used to reduce contrast-induced toxicity, but reduced iodine concentration and inconsistent acquisition conditions often produce uneven contrast attenuation and spatial misalignment between scans. In this context, we define dose-up translation as the computational process of synthetically enhancing low-dose contrast images to approximate the visual and diagnostic quality of full-dose acquisitions. These factors limit the effective use of routinely acquired imaging data for dose-up translation, particularly in veterinary abdominal CT where respiratory motion and postural variability further degrade anatomical correspondence. We present a weakly aligned enhancement framework designed to operate under spatial misalignment and limited paired data. Registration-based pseudo-references are constructed using a hybrid strategy that combines deformable anatomical alignment with feature-level correspondence. Dose-up translation is performed using structure-preserving translation with multi-scale consistency and edge-aware regularization to maintain anatomical boundaries. To address limited low-dose datasets, a two-stage knowledge transfer strategy transfers anatomical and contrast priors from abundant pre-contrast data. Quantitative evaluation demonstrated region-level contrast-to-noise ratio improvements of up to 31.5% (e.g., from 5.55 to 8.38 in the caudal vena cava (CVC), P < 0.05) compared with baseline enhancement methods across 1171 test slices. Experiments demonstrate consistent improvements in structural fidelity, distributional realism, and region-level vascular conspicuity compared with paired, unpaired, and synthetic-pairing baselines. These findings suggest that the dose-up translation of low-enhanced CT is better formulated as a weakly aligned domain adaptation problem rather than a strictly paired reconstruction task, enabling practical image translation under realistic clinical acquisition variability.

Journal of ImagingVol. 12(5)
Inha University (KR), Konkuk University (KR)
Openalex Percentile: Top 7%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.