Impact of Fault-Induced Tripping of Sink-Area Renewable Energy Sources on Power System Voltage Stability

Voltage stability assessment of a transmission interface is carried out by continuation power flow (CPF) using a fixed post-contingency operating condition. However, if legacy renewable energy sources (RESs) in the sink area are tripped during or following a fault, the actual post-fault operating point can differ from that assumed in the CPF study. This paper examines the effect of sink-area RES tripping on transmission interface voltage stability. The shift in the post-fault operating point caused by the loss of sink-area active power injection is explained using a two-bus equivalent, and the effect of reactive power support from connected RES on the transfer limit is also discussed. The proposed analysis is verified using a modified SAVNW test system in PSS/E. Two contingency scenarios were studied by applying a three-phase fault at the receiving-end bus and tripping one transmission interface line at fault clearing. The results show that sink-area RES tripping moves the post-fault operating point toward the nose point and reduces the voltage stability margin. The results also show that reactive power support from connected RES increases the transfer limit and leads to a larger margin. These effects should be considered in voltage stability assessment of transmission interfaces with legacy RES.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-04-25
DOI
https://doi.org/10.3390/en19092082
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Fault-Induced Tripping of Sink-Area Renewable Energy Sources on Power System Voltage Stability

Sangho Lee, Sangwon Min, Seungryul Lee, Heewon Shin
Energies
Power System Optimization and Stability
article

Impact of Fault-Induced Tripping of Sink-Area Renewable Energy Sources on Power System Voltage Stability

Sangho Lee, Sangwon Min, Seungryul Lee, Heewon Shin
article en

Abstract

Voltage stability assessment of a transmission interface is carried out by continuation power flow (CPF) using a fixed post-contingency operating condition. However, if legacy renewable energy sources (RESs) in the sink area are tripped during or following a fault, the actual post-fault operating point can differ from that assumed in the CPF study. This paper examines the effect of sink-area RES tripping on transmission interface voltage stability. The shift in the post-fault operating point caused by the loss of sink-area active power injection is explained using a two-bus equivalent, and the effect of reactive power support from connected RES on the transfer limit is also discussed. The proposed analysis is verified using a modified SAVNW test system in PSS/E. Two contingency scenarios were studied by applying a three-phase fault at the receiving-end bus and tripping one transmission interface line at fault clearing. The results show that sink-area RES tripping moves the post-fault operating point toward the nose point and reduces the voltage stability margin. The results also show that reactive power support from connected RES increases the transfer limit and leads to a larger margin. These effects should be considered in voltage stability assessment of transmission interfaces with legacy RES.

EnergiesVol. 19(9)
Korea Electrotechnology Research Institute (KR)
Korea Electrotechnology Research Institute, Ministry of Science and ICT, South Korea
Affordable and clean energy
Openalex Percentile: Top 7%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Fault-Induced Tripping of Sink-Area Renewable Energy Sources on Power System Voltage Stability — Sangho Lee, Sangwon Min, et al. · Energies (2026) | TGRS Research Map | TGRS