Ankle Prosthesis Force and Moment Estimation Using Wireless Strain Gauge Pyramid Adapter

Abstract Force and moment measurements are critical for powered ankle-foot prostheses, with over 73% of prototypes incorporating such sensors. Hardware complexity, compatibility limitations, and cost barriers currently limit widespread clinical adoption. This work presents four contributions using the commercial strain gauge based instrumented pyramid adapter Europa+: (1) hardware integration compatible with standard prosthetic components and minimal added bulk (275g, 37.5mm height); (2) an adaptive zero drift compensation algorithm achieving stable calibration within 2-3 steps for continuous long-term operation; (3) physics-informed linear regression models for real-time ankle force and moment estimation; and (4) experimental validation with 8 non-amputee participants using a passive prosthesis, and a preliminary single-participant evaluation with a two-degree-of-freedom (2-DOF) powered ankle-foot prosthesis in variable impedance closed loop operation. Results demonstrate exceptional axial force estimation (RMSE = 47+-20N, R^2 = 0.97+-0.03) and strong dorsi-plantar (DP) moment estimation (RMSE = 5.7+-2.3Nm, R^2 = 0.87+-0.06) across passive prosthesis participants, and these remain valid for the powered prosthesis. Inversion-eversion (IE) moment estimation achieves RMSE = 0.8+-0.2Nm and R^2 = 0.44+-0.16 on passive data, but performance improves when model parameters are derived from powered prosthesis gait with larger active IE range. This approach establishes a generalizable methodology applicable to strain gauge based instrumented pyramid adapters, offering a practical alternative to custom sensors while significantly reducing barriers to clinical implementation of ankle dynamics estimation in prosthetic applications.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2026-04-28
DOI
https://doi.org/10.1115/1.4071784
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ankle Prosthesis Force and Moment Estimation Using Wireless Strain Gauge Pyramid Adapter

Mo Rastgaar, Ahmed Soliman, Gabriel Torres Rivera, Adam Arabian et al.
Journal of Medical Devices
Prosthetics and Rehabilitation Robotics
article

Ankle Prosthesis Force and Moment Estimation Using Wireless Strain Gauge Pyramid Adapter

Mo Rastgaar, Ahmed Soliman, Gabriel Torres Rivera, Adam Arabian, Jorge Enrique Neira García
article en

Abstract

Abstract Force and moment measurements are critical for powered ankle-foot prostheses, with over 73% of prototypes incorporating such sensors. Hardware complexity, compatibility limitations, and cost barriers currently limit widespread clinical adoption. This work presents four contributions using the commercial strain gauge based instrumented pyramid adapter Europa+: (1) hardware integration compatible with standard prosthetic components and minimal added bulk (275g, 37.5mm height); (2) an adaptive zero drift compensation algorithm achieving stable calibration within 2-3 steps for continuous long-term operation; (3) physics-informed linear regression models for real-time ankle force and moment estimation; and (4) experimental validation with 8 non-amputee participants using a passive prosthesis, and a preliminary single-participant evaluation with a two-degree-of-freedom (2-DOF) powered ankle-foot prosthesis in variable impedance closed loop operation. Results demonstrate exceptional axial force estimation (RMSE = 47+-20N, R^2 = 0.97+-0.03) and strong dorsi-plantar (DP) moment estimation (RMSE = 5.7+-2.3Nm, R^2 = 0.87+-0.06) across passive prosthesis participants, and these remain valid for the powered prosthesis. Inversion-eversion (IE) moment estimation achieves RMSE = 0.8+-0.2Nm and R^2 = 0.44+-0.16 on passive data, but performance improves when model parameters are derived from powered prosthesis gait with larger active IE range. This approach establishes a generalizable methodology applicable to strain gauge based instrumented pyramid adapters, offering a practical alternative to custom sensors while significantly reducing barriers to clinical implementation of ankle dynamics estimation in prosthetic applications.

Journal of Medical Devices
Purdue University West Lafayette (US), Orthocare Innovations (United States) (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 8%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ankle Prosthesis Force and Moment Estimation Using Wireless Strain Gauge Pyramid Adapter — Mo Rastgaar, Ahmed Soliman, et al. · Journal of Medical Devices (2026) | TGRS Research Map | TGRS