Effect of additive manufacturing technology and print orientation on the accuracy of static guided implant surgery: An in vitro study

PURPOSE: The aim of this in vitro study was to investigate the effect of print orientation and printing technology on the accuracy of static computer-aided implant surgery (s-CAIS). MATERIALS AND METHODS: A cone beam computed tomography (CBCT) scan and a partially edentulous mandibular intraoral scan (IOS) of an unidentified patient missing the mandibular right first molar were used for this study. Fifty-two resin models were printed from the obtained IOS. Digital implant planning software CoDiagnostiX was used to virtually plan the implant based on a prosthetically driven approach. A tooth-supported surgical guide was designed, and the resultant STL files were then used to manufacture 52 different guides. Two different printing technologies were employed: stereolithography (SLA) and digital light processing (DLP). The groups were further subdivided according to print orientation into 0° and 45° orientations, with 13 guides per group (n = 13). Fifty-two fully guided implants were placed in their respective models. Scan bodies were placed on each implant, and an intraoral implant scan was obtained. Post-placement STL files were then imported into the CoDiagnostiX treatment evaluation tool to assess the accuracy of the placed implants compared to the planned ones. Three different parameters were assessed: implant angular deviation, deviation at the entry point, and deviation at the apex. Two-way analysis of variance (ANOVA) and post hoc Tukey pairwise comparison tests were used to compare the means, with a significance level set at p < 0.05 (α = 0.05) using the R programming language. RESULTS: No statistically significant difference was observed in mean angular deviation among the groups (p > 0.05). At the entry point, the 45° SLA group demonstrated the lowest mean deviation (0.86 ± 0.13 mm), which was significantly lower than 0° SLA (1.35 ± 0.22 mm), 0° DLP (1.23 ± 0.20 mm), and 45° DLP (1.11 ± 0.29 mm) (p < 0.05). No significant differences were observed between 0° DLP and 0° SLA or between 0° DLP and 45° DLP. At the apical level, the 45° SLA group exhibited the lowest mean deviation (1.16 ± 0.23 mm) and differed significantly from both 0° SLA (1.45 ± 0.25 mm) and 0° DLP (1.49 ± 0.32 mm) (p < 0.05), whereas no significant differences were found between 45° SLA and 45° DLP. CONCLUSION: Overall, print orientation (0° vs. 45°) and printing technology (SLA vs. DLP) did not significantly affect angular deviation. For the SLA group, printing at a 45° orientation significantly reduced the offset at both the entry point and the apex compared to the 0° orientation, with results favoring the 45° orientation. In contrast, print orientation did not significantly influence accuracy in the DLP group.

Authors

Institutions

Publication Details

Journal
Journal of Prosthodontics
Published
2026-04-28
DOI
https://doi.org/10.1111/jopr.70152
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of additive manufacturing technology and print orientation on the accuracy of static guided implant surgery: An in vitro study

Sherif Hosney, Nader Abdulhameed, May Alshammari, Sara Amini
Journal of Prosthodontics
Dental Implant Techniques and Outcomes
article

Effect of additive manufacturing technology and print orientation on the accuracy of static guided implant surgery: An in vitro study

Sherif Hosney, Nader Abdulhameed, May Alshammari, Sara Amini
article en

Abstract

PURPOSE: The aim of this in vitro study was to investigate the effect of print orientation and printing technology on the accuracy of static computer-aided implant surgery (s-CAIS). MATERIALS AND METHODS: A cone beam computed tomography (CBCT) scan and a partially edentulous mandibular intraoral scan (IOS) of an unidentified patient missing the mandibular right first molar were used for this study. Fifty-two resin models were printed from the obtained IOS. Digital implant planning software CoDiagnostiX was used to virtually plan the implant based on a prosthetically driven approach. A tooth-supported surgical guide was designed, and the resultant STL files were then used to manufacture 52 different guides. Two different printing technologies were employed: stereolithography (SLA) and digital light processing (DLP). The groups were further subdivided according to print orientation into 0° and 45° orientations, with 13 guides per group (n = 13). Fifty-two fully guided implants were placed in their respective models. Scan bodies were placed on each implant, and an intraoral implant scan was obtained. Post-placement STL files were then imported into the CoDiagnostiX treatment evaluation tool to assess the accuracy of the placed implants compared to the planned ones. Three different parameters were assessed: implant angular deviation, deviation at the entry point, and deviation at the apex. Two-way analysis of variance (ANOVA) and post hoc Tukey pairwise comparison tests were used to compare the means, with a significance level set at p < 0.05 (α = 0.05) using the R programming language. RESULTS: No statistically significant difference was observed in mean angular deviation among the groups (p > 0.05). At the entry point, the 45° SLA group demonstrated the lowest mean deviation (0.86 ± 0.13 mm), which was significantly lower than 0° SLA (1.35 ± 0.22 mm), 0° DLP (1.23 ± 0.20 mm), and 45° DLP (1.11 ± 0.29 mm) (p < 0.05). No significant differences were observed between 0° DLP and 0° SLA or between 0° DLP and 45° DLP. At the apical level, the 45° SLA group exhibited the lowest mean deviation (1.16 ± 0.23 mm) and differed significantly from both 0° SLA (1.45 ± 0.25 mm) and 0° DLP (1.49 ± 0.32 mm) (p < 0.05), whereas no significant differences were found between 45° SLA and 45° DLP. CONCLUSION: Overall, print orientation (0° vs. 45°) and printing technology (SLA vs. DLP) did not significantly affect angular deviation. For the SLA group, printing at a 45° orientation significantly reduced the offset at both the entry point and the apex compared to the 0° orientation, with results favoring the 45° orientation. In contrast, print orientation did not significantly influence accuracy in the DLP group.

Journal of Prosthodontics
University of Florida (US)
Openalex Percentile: Top 9%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.