Patch-Type Microwave Resonant Sensor Based on a Complementary Split-Ring Resonator for Monitoring Glucose Concentration Under Static and Dynamic Conditions

This study designs a complementary split-ring resonator (CSRR)-based 5 GHz patch-type microwave resonant sensor for measuring the concentrations of glucose solutions under static and dynamic conditions. Circulating glucose solutions were used to simulate blood glucose, and the CSRR sensor was operated over a frequency range of 4.8–5.0 GHz. The planar microstrip configuration of the CSRR creates a highly confined electric field within the sensing area. When glucose solution covers or flows through the sensing region, the dielectric loading changes, altering the resonance condition and inducing perturbations. Identifiable measurement features can be extracted from data on the scattering parameter S11. Glucose solutions with concentrations ranging from 5% to 65% were used to examine the response of the proposed sensor. The concentrations of these solutions were estimated on the basis of resonant frequency shifts, and variation in S21 at the CSRR’s resonant frequency (or at a fixed frequency corresponding to the maximum slope) was also analyzed.

Authors

Publication Details

Journal
Sensors
Published
2026-04-27
DOI
https://doi.org/10.3390/s26092710
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patch-Type Microwave Resonant Sensor Based on a Complementary Split-Ring Resonator for Monitoring Glucose Concentration Under Static and Dynamic Conditions

Wei-Lung Wu
Sensors
Microwave and Dielectric Measurement Techniques
article

Patch-Type Microwave Resonant Sensor Based on a Complementary Split-Ring Resonator for Monitoring Glucose Concentration Under Static and Dynamic Conditions

Wei-Lung Wu
article en

Abstract

This study designs a complementary split-ring resonator (CSRR)-based 5 GHz patch-type microwave resonant sensor for measuring the concentrations of glucose solutions under static and dynamic conditions. Circulating glucose solutions were used to simulate blood glucose, and the CSRR sensor was operated over a frequency range of 4.8–5.0 GHz. The planar microstrip configuration of the CSRR creates a highly confined electric field within the sensing area. When glucose solution covers or flows through the sensing region, the dielectric loading changes, altering the resonance condition and inducing perturbations. Identifiable measurement features can be extracted from data on the scattering parameter S11. Glucose solutions with concentrations ranging from 5% to 65% were used to examine the response of the proposed sensor. The concentrations of these solutions were estimated on the basis of resonant frequency shifts, and variation in S21 at the CSRR’s resonant frequency (or at a fixed frequency corresponding to the maximum slope) was also analyzed.

SensorsVol. 26(9)
National Kaohsiung University of Science and Technology
Openalex Percentile: Top 8%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.