Self-Explaining Neural Networks for Transparent Parkinson’s Disease Screening

Transparent clinical decision-making remains a critical barrier to deploying deep learning in medical diagnosis. Post hoc explanation methods approximate model behaviour after training but cannot guarantee that explanations faithfully reflect the underlying reasoning. This study proposes a Self-Explaining Neural Network (SENN) for Parkinson’s Disease (PD) screening via Ground Reaction Force (GRF) gait analysis, enforcing intrinsic interpretability through learnable basis concepts and input-dependent relevance scores computed jointly with the prediction. The architecture combines a four-block residual CNN backbone with stochastic depth regularisation, a 16-concept encoder with diversity and stability constraints, and temperature-scaled probability calibration for reliable clinical operating points. Evaluated on the PhysioNet Gait in Parkinson’s Disease dataset (306 subjects, 16 GRF sensors per foot), SENN achieves a subject-level ROC-AUC of 0.916 [95% CI: 0.867–0.964], sensitivity of 0.913 [0.862–0.963], specificity of 0.671 [0.485–0.858], and Average Precision of 0.942 [0.918–0.967], reported across five independent random seeds. Comparative evaluation against four deep learning baselines—CNN-Residual, BiLSTM, CNN-LSTM, and CNN-Attention—confirms that the interpretability constraints impose no statistically significant reduction in discriminative performance, with all pairwise ROC-AUC confidence intervals overlapping. Concept-level analysis reveals that the three most discriminative concepts correspond to disrupted midfoot loading patterns, increased step-length variability, and bilateral cadence asymmetry—all established biomechanical hallmarks of parkinsonian gait—providing clinically grounded, patient-specific explanations without post hoc approximation. These findings demonstrate that rigorous intrinsic interpretability and competitive predictive accuracy are simultaneously achievable in deep gait analysis, supporting the clinical adoption of transparent diagnostic AI.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-25
DOI
https://doi.org/10.3390/s26092671
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Explaining Neural Networks for Transparent Parkinson’s Disease Screening

Ahmad AA Alkhatib, Tee Connie, Mahmoud E. Farfoura
Sensors
Balance, Gait, and Falls Prevention
article

Self-Explaining Neural Networks for Transparent Parkinson’s Disease Screening

Ahmad AA Alkhatib, Tee Connie, Mahmoud E. Farfoura
article en

Abstract

Transparent clinical decision-making remains a critical barrier to deploying deep learning in medical diagnosis. Post hoc explanation methods approximate model behaviour after training but cannot guarantee that explanations faithfully reflect the underlying reasoning. This study proposes a Self-Explaining Neural Network (SENN) for Parkinson’s Disease (PD) screening via Ground Reaction Force (GRF) gait analysis, enforcing intrinsic interpretability through learnable basis concepts and input-dependent relevance scores computed jointly with the prediction. The architecture combines a four-block residual CNN backbone with stochastic depth regularisation, a 16-concept encoder with diversity and stability constraints, and temperature-scaled probability calibration for reliable clinical operating points. Evaluated on the PhysioNet Gait in Parkinson’s Disease dataset (306 subjects, 16 GRF sensors per foot), SENN achieves a subject-level ROC-AUC of 0.916 [95% CI: 0.867–0.964], sensitivity of 0.913 [0.862–0.963], specificity of 0.671 [0.485–0.858], and Average Precision of 0.942 [0.918–0.967], reported across five independent random seeds. Comparative evaluation against four deep learning baselines—CNN-Residual, BiLSTM, CNN-LSTM, and CNN-Attention—confirms that the interpretability constraints impose no statistically significant reduction in discriminative performance, with all pairwise ROC-AUC confidence intervals overlapping. Concept-level analysis reveals that the three most discriminative concepts correspond to disrupted midfoot loading patterns, increased step-length variability, and bilateral cadence asymmetry—all established biomechanical hallmarks of parkinsonian gait—providing clinically grounded, patient-specific explanations without post hoc approximation. These findings demonstrate that rigorous intrinsic interpretability and competitive predictive accuracy are simultaneously achievable in deep gait analysis, supporting the clinical adoption of transparent diagnostic AI.

SensorsVol. 26(9)
Al-Zaytoonah University of Jordan (JO), Multimedia University (MY)
Multimedia University, University of Jordan, Al-Zaytoonah University of Jordan
Reduced inequalities
Openalex Percentile: Top 4%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.