Safety and efficacy of stand-alone and hybrid thoracoscopic atrial fibrillation ablation

OBJECTIVES: This study aimed to evaluate the long-term efficacy and safety of isolated and hybrid thoracoscopic AF ablation using a bipolar irrigated radiofrequency clamp in a multicentre registry. METHODS: A retrospective multicentre registry of patients undergoing AF ablation using the bipolar clamp was conducted over the past 13 years (2010-2023). The primary efficacy outcome was freedom of atrial tachyarrhythmias (ATA), with and without the use of Class I/III antiarrhythmic drugs (AAD). AAD use during follow-up was not uniformly documented across centers. The primary safety outcome was the rate of periprocedural complications. RESULTS: The cohort of 678 patients consisted of a minority of female patients (17.4%), with most patients having long-standing persistent AF (LSPAF) (66.7%), a mean duration of 61 months of AF duration and 33.3% had undergone prior catheter ablation. Freedom from ATA while allowing Class I/III AAD use was 82.3%, 71.5%, and 52.4% at 1, 3, and 5 years, respectively. Freedom from ATA off Class I/III AAD declined from 71.7% at 1 year to 44.2% at 5 years, underscoring the progressive nature of AF and the need for long-term rhythm strategies. Women presented with a more advanced cardiovascular risk profile than men, including older age (60.3 vs 57.3 years), higher CHA2DS2-VA-scores, and more comorbidities. Despite these differences, there were no significant sex-based differences in long-term ATA freedom. There were no significant unadjusted differences in long-term ATA freedom between PAF and non-PAF. Major complication rate was low. CONCLUSIONS: Isolated and hybrid thoracoscopic AF ablation using the Gemini Clamp demonstrated favorable outcomes with a low complication rate. However, variability in ATA detection methods among centers may have influenced the primary outcome and should be considered when interpreting long-term efficacy results.

Authors

Institutions

Publication Details

Journal
European Journal of Cardio-Thoracic Surgery
Published
2026-04-24
DOI
https://doi.org/10.1093/ejcts/ezag161
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety and efficacy of stand-alone and hybrid thoracoscopic atrial fibrillation ablation

Michał Kawczyński, Alexander Bogachev‐Prokophiev, Bart Maesen, Henri Gruwez et al.
European Journal of Cardio-Thoracic Surgery
Atrial Fibrillation Management and Outcomes
article

Safety and efficacy of stand-alone and hybrid thoracoscopic atrial fibrillation ablation

Michał Kawczyński, Alexander Bogachev‐Prokophiev, Bart Maesen, Henri Gruwez, Ricardo Cocchieri, Niels Verberkmoes, А С Зотов, Herbert Gutermann, Luca Aerts, Sacha P. Salzberg, Oleg Shelest, Justin Luermans, T J Van Brakel, Alexandr Troitskiy, Robert Khabazov, Samuel Heuts, Dmitry Elesin, Eva Verbeek, Laurent Pison
article en

Abstract

OBJECTIVES: This study aimed to evaluate the long-term efficacy and safety of isolated and hybrid thoracoscopic AF ablation using a bipolar irrigated radiofrequency clamp in a multicentre registry. METHODS: A retrospective multicentre registry of patients undergoing AF ablation using the bipolar clamp was conducted over the past 13 years (2010-2023). The primary efficacy outcome was freedom of atrial tachyarrhythmias (ATA), with and without the use of Class I/III antiarrhythmic drugs (AAD). AAD use during follow-up was not uniformly documented across centers. The primary safety outcome was the rate of periprocedural complications. RESULTS: The cohort of 678 patients consisted of a minority of female patients (17.4%), with most patients having long-standing persistent AF (LSPAF) (66.7%), a mean duration of 61 months of AF duration and 33.3% had undergone prior catheter ablation. Freedom from ATA while allowing Class I/III AAD use was 82.3%, 71.5%, and 52.4% at 1, 3, and 5 years, respectively. Freedom from ATA off Class I/III AAD declined from 71.7% at 1 year to 44.2% at 5 years, underscoring the progressive nature of AF and the need for long-term rhythm strategies. Women presented with a more advanced cardiovascular risk profile than men, including older age (60.3 vs 57.3 years), higher CHA2DS2-VA-scores, and more comorbidities. Despite these differences, there were no significant sex-based differences in long-term ATA freedom. There were no significant unadjusted differences in long-term ATA freedom between PAF and non-PAF. Major complication rate was low. CONCLUSIONS: Isolated and hybrid thoracoscopic AF ablation using the Gemini Clamp demonstrated favorable outcomes with a low complication rate. However, variability in ATA detection methods among centers may have influenced the primary outcome and should be considered when interpreting long-term efficacy results.

European Journal of Cardio-Thoracic Surgery
Radboud University Nijmegen (NL), Maastricht University Medical Centre (NL), Catharina Ziekenhuis (NL), Maastricht University (NL), Schön Klinik Vogtareuth (DE), Klinik Hirslanden (CH), OLVG (NL), Federal Research and Clinical Center of Physical-Chemical Medicine named after Y.M. Lopukhin (RU), Ziekenhuis Oost-Limburg (BE), Meshalkin National Medical Research Center (RU)
Gender equality
Openalex Percentile: Top 10%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.