High-Frequency Coupled-Resonator CMUT with Stepped Cavity for Enhanced Sensitivity and Bandwidth in Acoustic Emission Detection

Acoustic emission (AE) monitoring in metal additive manufacturing (AM) requires compact sensors capable of high-frequency operation, broad bandwidth, and high sensitivity. However, increasing structural stiffness to achieve high resonance frequencies typically reduces electromechanical sensitivity. This work presents a finite element study of a coupled-resonator capacitive micromachined ultrasonic transducer (CMUT) designed to address this trade-off. The proposed architecture integrates three mechanically coupled silicon membranes with a stepped capacitive cavity that increases capacitance while preserving structural stiffness, enabling enhanced sensitivity without compromising high-frequency operation. COMSOL Multiphysics simulations were used to evaluate modal characteristics and frequency response under DC pre-stressed conditions. Modal coupling produced closely spaced resonances that broadened the effective bandwidth, while the stepped cavity significantly increased voltage output through improved electromechanical coupling. Compared to a single-resonator flat-cavity design, the coupled stepped-cavity configuration demonstrated nearly a threefold enhancement in output voltage while maintaining operation near 100 kHz. Additionally, adjusting the central resonator length enabled controlled frequency tuning for scalable array implementation. These results establish a proof of concept for a high-frequency, high-sensitivity micro-electro-mechanical systems (MEMS) CMUT architecture suitable for distributed AE monitoring in advanced manufacturing environments.

Authors

Institutions

Publication Details

Journal
Metrology
Published
2026-04-28
DOI
https://doi.org/10.3390/metrology6020029
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Frequency Coupled-Resonator CMUT with Stepped Cavity for Enhanced Sensitivity and Bandwidth in Acoustic Emission Detection

Fadi Alsaleem, Sulaiman Mohaidat, Mohammad Okour, Mutaz Al Fayad
Metrology
Ultrasound Imaging and Elastography
article

High-Frequency Coupled-Resonator CMUT with Stepped Cavity for Enhanced Sensitivity and Bandwidth in Acoustic Emission Detection

Fadi Alsaleem, Sulaiman Mohaidat, Mohammad Okour, Mutaz Al Fayad
article en

Abstract

Acoustic emission (AE) monitoring in metal additive manufacturing (AM) requires compact sensors capable of high-frequency operation, broad bandwidth, and high sensitivity. However, increasing structural stiffness to achieve high resonance frequencies typically reduces electromechanical sensitivity. This work presents a finite element study of a coupled-resonator capacitive micromachined ultrasonic transducer (CMUT) designed to address this trade-off. The proposed architecture integrates three mechanically coupled silicon membranes with a stepped capacitive cavity that increases capacitance while preserving structural stiffness, enabling enhanced sensitivity without compromising high-frequency operation. COMSOL Multiphysics simulations were used to evaluate modal characteristics and frequency response under DC pre-stressed conditions. Modal coupling produced closely spaced resonances that broadened the effective bandwidth, while the stepped cavity significantly increased voltage output through improved electromechanical coupling. Compared to a single-resonator flat-cavity design, the coupled stepped-cavity configuration demonstrated nearly a threefold enhancement in output voltage while maintaining operation near 100 kHz. Additionally, adjusting the central resonator length enabled controlled frequency tuning for scalable array implementation. These results establish a proof of concept for a high-frequency, high-sensitivity micro-electro-mechanical systems (MEMS) CMUT architecture suitable for distributed AE monitoring in advanced manufacturing environments.

MetrologyVol. 6(2)
University of Nebraska–Lincoln (US), University of Nebraska at Omaha (US)
U.S. Department of Energy
Affordable and clean energy
Openalex Percentile: Top 6%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.