CFD Comparison of Al2O3 and ZnO Ceramic Coatings on Non-Insulated Copper Heat Exchangers

Non-insulated heat exchangers in gas-to-gas service lose substantial energy to the surroundings. This study evaluates Al2O3 and ZnO ceramic coatings (200 μm) as passive thermal retention layers on the inner surface of the outer tube in a copper double-pipe heat exchanger, using 3D CFD simulations verified for internal consistency against Log Mean Heat Transfer Rate analytical solutions. Six cases were modelled: three coating conditions across parallel-flow and counter-flow configurations under laminar conditions (Rei≈525, Reo≈192) with air as the working fluid. The coating elevates the outer tube inner wall temperature T3, increasing the convective driving force to the cold fluid while suppressing ambient dissipation. In parallel flow, Al2O3 increases the net inter-fluid heat transfer rate by 35.7% and reduces ambient losses by 81.4%; ZnO achieves 30.9% and 70.4%, respectively. In counter-flow, Al2O3 yields a 26.6% enhancement and 73.2% loss reduction. The coated parallel-flow configuration outperforms the uncoated counter-flow baseline. Thermal circuit analysis shows that Al2O3 superiority arises from its higher conductivity (40 vs. 19 W m−1 K−1), which sustains a higher equilibrium T3 and a heat partition ratio of 11.84 versus 7.17 for ZnO. These results show that a single ceramic coating layer can recover a large fraction of the thermal energy lost through non-insulated walls, offering a low-cost, retrofit-compatible pathway to improve the energy efficiency of gas-to-gas heat exchangers in HVAC, building energy recovery, and industrial process heat applications.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-04-27
DOI
https://doi.org/10.3390/en19092110
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFD Comparison of Al2O3 and ZnO Ceramic Coatings on Non-Insulated Copper Heat Exchangers

Hussein Kokash, Mwafak Shakoor, Ammar Bany-Ata, Mohammad Kokash et al.
Energies
Adsorption and Cooling Systems
article

CFD Comparison of Al2O3 and ZnO Ceramic Coatings on Non-Insulated Copper Heat Exchangers

Hussein Kokash, Mwafak Shakoor, Ammar Bany-Ata, Mohammad Kokash, Sameeh Baqain
article en

Abstract

Non-insulated heat exchangers in gas-to-gas service lose substantial energy to the surroundings. This study evaluates Al2O3 and ZnO ceramic coatings (200 μm) as passive thermal retention layers on the inner surface of the outer tube in a copper double-pipe heat exchanger, using 3D CFD simulations verified for internal consistency against Log Mean Heat Transfer Rate analytical solutions. Six cases were modelled: three coating conditions across parallel-flow and counter-flow configurations under laminar conditions (Rei≈525, Reo≈192) with air as the working fluid. The coating elevates the outer tube inner wall temperature T3, increasing the convective driving force to the cold fluid while suppressing ambient dissipation. In parallel flow, Al2O3 increases the net inter-fluid heat transfer rate by 35.7% and reduces ambient losses by 81.4%; ZnO achieves 30.9% and 70.4%, respectively. In counter-flow, Al2O3 yields a 26.6% enhancement and 73.2% loss reduction. The coated parallel-flow configuration outperforms the uncoated counter-flow baseline. Thermal circuit analysis shows that Al2O3 superiority arises from its higher conductivity (40 vs. 19 W m−1 K−1), which sustains a higher equilibrium T3 and a heat partition ratio of 11.84 versus 7.17 for ZnO. These results show that a single ceramic coating layer can recover a large fraction of the thermal energy lost through non-insulated walls, offering a low-cost, retrofit-compatible pathway to improve the energy efficiency of gas-to-gas heat exchangers in HVAC, building energy recovery, and industrial process heat applications.

EnergiesVol. 19(9)
American University of Madaba (JO), University of Arkansas at Fayetteville (US)
Affordable and clean energy
Openalex Percentile: Top 12%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.