Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent

Background: Acute type A aortic dissection (ATAAD) is a life-threatening condition that may be complicated by malperfusion, particularly in patients with prior aortic interventions such as Thoracic Endovascular Aortic Repair (TEVAR). Management becomes increasingly complex when the dissection involves supra-aortic branches and compromises previously placed stents. Methods: We report the case of a 58-year-old male presenting with ATAAD and left lower limb paralysis, with a history of prior TEVAR. Imaging demonstrated an entry tear in the ascending aorta with extension into the distal left main and supra-aortic branches, resulting in a dissection flap obstructing the proximal end of the TEVAR stent. The patient underwent emergency surgical intervention including a Bentall procedure, coronary artery bypass grafting (CABG), and deployment of a small Ascyrus Medical Dissection Stent (AMDS) distally within the TEVAR stent. Pre-operatively, the patient had severe lower limb ischemia due to near-complete obstruction of distal flow. Results: Following surgical intervention, there was restoration of true lumen perfusion with resolution of malperfusion. The patient was successfully weaned from cardiopulmonary bypass, extubated on post-operative day 4, and discharged on day 7 with stable hemodynamics and intact bilateral lower limb perfusion. Post-operative computed tomography (CT) demonstrated a well-seated AMDS with no evidence of ongoing false lumen perfusion. At 30-day follow-up, there was no clinical or biochemical evidence of organ malperfusion. Conclusions: The use of an AMDS deployed within a pre-existing TEVAR stent may represent an effective strategy for managing complex ATAAD with malperfusion, particularly in cases requiring combined surgical interventions.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-04-27
DOI
https://doi.org/10.3390/jcm15093329
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent

Pouya Nezafati, Bruce French, Robert Grant
Journal of Clinical Medicine
Aortic Disease and Treatment Approaches
article

Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent

Pouya Nezafati, Bruce French, Robert Grant
article en

Abstract

Background: Acute type A aortic dissection (ATAAD) is a life-threatening condition that may be complicated by malperfusion, particularly in patients with prior aortic interventions such as Thoracic Endovascular Aortic Repair (TEVAR). Management becomes increasingly complex when the dissection involves supra-aortic branches and compromises previously placed stents. Methods: We report the case of a 58-year-old male presenting with ATAAD and left lower limb paralysis, with a history of prior TEVAR. Imaging demonstrated an entry tear in the ascending aorta with extension into the distal left main and supra-aortic branches, resulting in a dissection flap obstructing the proximal end of the TEVAR stent. The patient underwent emergency surgical intervention including a Bentall procedure, coronary artery bypass grafting (CABG), and deployment of a small Ascyrus Medical Dissection Stent (AMDS) distally within the TEVAR stent. Pre-operatively, the patient had severe lower limb ischemia due to near-complete obstruction of distal flow. Results: Following surgical intervention, there was restoration of true lumen perfusion with resolution of malperfusion. The patient was successfully weaned from cardiopulmonary bypass, extubated on post-operative day 4, and discharged on day 7 with stable hemodynamics and intact bilateral lower limb perfusion. Post-operative computed tomography (CT) demonstrated a well-seated AMDS with no evidence of ongoing false lumen perfusion. At 30-day follow-up, there was no clinical or biochemical evidence of organ malperfusion. Conclusions: The use of an AMDS deployed within a pre-existing TEVAR stent may represent an effective strategy for managing complex ATAAD with malperfusion, particularly in cases requiring combined surgical interventions.

Journal of Clinical MedicineVol. 15(9)
John Hunter Hospital (AU), Liverpool Hospital (AU)
Good health and well-being
Openalex Percentile: Top 6%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent — Pouya Nezafati, Bruce French, et al. · Journal of Clinical Medicine (2026) | TGRS Research Map | TGRS