Validity of the eJamar Game Controller for Measuring Hand Range of Motion and Grip Strength in Hand Rehabilitation

Hand range of motion (ROM) measurement is crucial for diagnosing joint limitations, tracking rehabilitation progress, and creating personalized treatment plans. In recent years, exergames combined with dedicated game controllers have emerged as promising tools to complement traditional hand rehabilitation; however, their validity as motor function assessment tools remains insufficiently explored. This study evaluates the validity of the eJamar game controller as a tool for measuring hand ROM and hand grip strength (HGS), by comparing its outputs with standard goniometry and dynamometry. In a prior technical validation using a robotic arm under controlled conditions, the device showed a mean error of approximately 1.5°, indicating high measurement precision under ideal conditions. In the clinical validation with 32 patients undergoing hand rehabilitation, performance was movement-dependent. Pronation and supination showed strong agreement (MAE < 3°) and higher agreement compared with other movements, whereas flexion, extension, and radial-ulnar deviation exhibited weaker correlations and substantially higher errors (around 20°). In contrast, grip strength measurements for more and less affected hands, respectively, showed high correlation (0.88–0.91) and moderate agreement (ICC 0.81–0.66) with MAE values around 4 kg-f. Overall, results suggest that the eJamar shows preliminary suitability for assessing HGS and forearm pronation and supination in clinical settings. However, for HGS, agreement should be interpreted with caution due to the observed bias and error levels, indicating that further validation and calibration are required before stronger clinical claims can be made. For wrist flexion, extension, and radial-ulnar deviation, the device currently shows limited accuracy and requires further improvement.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-04-26
DOI
https://doi.org/10.3390/eng7050197
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validity of the eJamar Game Controller for Measuring Hand Range of Motion and Grip Strength in Hand Rehabilitation

Andrés Cela, Edwin Daniel Oña, Alberto Jardón
Eng—Advances in Engineering
Stroke Rehabilitation and Recovery
article

Validity of the eJamar Game Controller for Measuring Hand Range of Motion and Grip Strength in Hand Rehabilitation

Andrés Cela, Edwin Daniel Oña, Alberto Jardón
article en

Abstract

Hand range of motion (ROM) measurement is crucial for diagnosing joint limitations, tracking rehabilitation progress, and creating personalized treatment plans. In recent years, exergames combined with dedicated game controllers have emerged as promising tools to complement traditional hand rehabilitation; however, their validity as motor function assessment tools remains insufficiently explored. This study evaluates the validity of the eJamar game controller as a tool for measuring hand ROM and hand grip strength (HGS), by comparing its outputs with standard goniometry and dynamometry. In a prior technical validation using a robotic arm under controlled conditions, the device showed a mean error of approximately 1.5°, indicating high measurement precision under ideal conditions. In the clinical validation with 32 patients undergoing hand rehabilitation, performance was movement-dependent. Pronation and supination showed strong agreement (MAE < 3°) and higher agreement compared with other movements, whereas flexion, extension, and radial-ulnar deviation exhibited weaker correlations and substantially higher errors (around 20°). In contrast, grip strength measurements for more and less affected hands, respectively, showed high correlation (0.88–0.91) and moderate agreement (ICC 0.81–0.66) with MAE values around 4 kg-f. Overall, results suggest that the eJamar shows preliminary suitability for assessing HGS and forearm pronation and supination in clinical settings. However, for HGS, agreement should be interpreted with caution due to the observed bias and error levels, indicating that further validation and calibration are required before stronger clinical claims can be made. For wrist flexion, extension, and radial-ulnar deviation, the device currently shows limited accuracy and requires further improvement.

Eng—Advances in EngineeringVol. 7(5)
National Polytechnic School (EC), Universidad Carlos III de Madrid (ES)
European Commission, Escuela Politécnica Nacional, Instituto de Salud Carlos III
Openalex Percentile: Top 8%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.