Evaluation of breast lesions using a newly developed 3D breast ultrasound imaging device: a preliminary study on efficacy and validity

To evaluate the image quality and diagnostic performance of a newly developed three-dimensional automated breast ultrasound (ABUS) system, MammouS-N, characterized by mammography-like geometry. In this prospective study of 121 women with 139 breast lesions, MammouS-N images were obtained in three different projections and reviewed in consensus by two breast radiologists blinded to prior imaging and pathology. Image quality was rated for six parameters. Lesion detectability and BI-RADS categories were compared between MammouS-N and hand-held ultrasound (HHUS), and their concordance was assessed using κ statistics. Diagnostic performance was assessed using the receiver operating characteristic (ROC) analysis with pathology as the reference standard. MammouS-N achieved diagnostically acceptable image quality (score ≥ 4) in over 90% of cases and near-complete coverage in 98.6% of breasts. Of 139 lesions, 131 (94.2%) were visualized, including 88 of 92 malignant lesions (95.7%). The area under the ROC curve for malignancy detection was 0.893 for MammouS-N (95% CI, 0.844-0.943) and 0.923 (95% CI, 0.885-0.962) for HHUS, without a significant difference (p = 0.207). BI-RADS concordance between MammouS-N and HHUS showed moderate-to-substantial agreement (Cohen's κ = 0.45; weighted κ = 0.65), with a mild benign-leaning tendency, as downgrades exceeded upgrades (2.1% of benign and 12.0% of malignant lesions were downgraded relative to HHUS. MammouS-N demonstrated high image quality, excellent lesion detectability, and comparable diagnostic concordance with HHUS. Its mammography-aligned geometry facilitates spatial correspondence across modalities, supporting its potential as a complementary imaging tool for breast cancer screening.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-27
DOI
https://doi.org/10.1038/s41598-026-48519-x
Primary Topic
Breast Lesions and Carcinomas
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of breast lesions using a newly developed 3D breast ultrasound imaging device: a preliminary study on efficacy and validity

Miribi Rho, Kyunghwa Han, Min Jung Kim
Scientific Reports
Breast Lesions and Carcinomas
article

Evaluation of breast lesions using a newly developed 3D breast ultrasound imaging device: a preliminary study on efficacy and validity

Miribi Rho, Kyunghwa Han, Min Jung Kim
article en

Abstract

To evaluate the image quality and diagnostic performance of a newly developed three-dimensional automated breast ultrasound (ABUS) system, MammouS-N, characterized by mammography-like geometry. In this prospective study of 121 women with 139 breast lesions, MammouS-N images were obtained in three different projections and reviewed in consensus by two breast radiologists blinded to prior imaging and pathology. Image quality was rated for six parameters. Lesion detectability and BI-RADS categories were compared between MammouS-N and hand-held ultrasound (HHUS), and their concordance was assessed using κ statistics. Diagnostic performance was assessed using the receiver operating characteristic (ROC) analysis with pathology as the reference standard. MammouS-N achieved diagnostically acceptable image quality (score ≥ 4) in over 90% of cases and near-complete coverage in 98.6% of breasts. Of 139 lesions, 131 (94.2%) were visualized, including 88 of 92 malignant lesions (95.7%). The area under the ROC curve for malignancy detection was 0.893 for MammouS-N (95% CI, 0.844-0.943) and 0.923 (95% CI, 0.885-0.962) for HHUS, without a significant difference (p = 0.207). BI-RADS concordance between MammouS-N and HHUS showed moderate-to-substantial agreement (Cohen's κ = 0.45; weighted κ = 0.65), with a mild benign-leaning tendency, as downgrades exceeded upgrades (2.1% of benign and 12.0% of malignant lesions were downgraded relative to HHUS. MammouS-N demonstrated high image quality, excellent lesion detectability, and comparable diagnostic concordance with HHUS. Its mammography-aligned geometry facilitates spatial correspondence across modalities, supporting its potential as a complementary imaging tool for breast cancer screening.

Scientific Reports
Yonsei University (KR), Severance Hospital (KR), Yonsei University Health System (KR)
Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of Science and ICT, South Korea
Good health and well-being
Openalex Percentile: Top 6%
Breast Lesions and Carcinomas
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.