Absorption Mode Broadband 2D MS for Proteomics and Metabolomics

Two-dimensional mass spectrometry (2D MS) is a method for tandem mass spectrometry that enables the correlation between precursor and fragment ions without the need for ion isolation. On a Fourier transform ion cyclotron resonance mass spectrometer, the phase correction functions for absorption mode data processing were found to be linear in the precursor ion dimension and quadratic in the fragment ion dimension. Phase-corrected absorption mode data processing on limited data sets has previously shown improvements in signal-to-noise ratio (SNR) and resolving power by a factor of 2. Here, we have expanded phase-corrected absorption mode data processing to 2D mass spectra regardless of size and frequency range. We have applied phase-corrected absorption mode 2D MS to top-down analysis of variously oxidized ubiquitin proteoforms generated by fast photochemical oxidation of proteins (FPOP) and to an extract of ergot alkaloids. We show that phase-corrected absorption mode data processing significantly improves both the SNR and the resolving power of the 2D mass spectrum compared to standard magnitude mode in terms of sequence coverage in top-down proteomics, as well as the accuracy of precursor-fragment correlation in metabolomics.

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-04-27
DOI
https://doi.org/10.1021/jasms.6c00007
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Absorption Mode Broadband 2D MS for Proteomics and Metabolomics

Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
article

Absorption Mode Broadband 2D MS for Proteomics and Metabolomics

article en

Abstract

Two-dimensional mass spectrometry (2D MS) is a method for tandem mass spectrometry that enables the correlation between precursor and fragment ions without the need for ion isolation. On a Fourier transform ion cyclotron resonance mass spectrometer, the phase correction functions for absorption mode data processing were found to be linear in the precursor ion dimension and quadratic in the fragment ion dimension. Phase-corrected absorption mode data processing on limited data sets has previously shown improvements in signal-to-noise ratio (SNR) and resolving power by a factor of 2. Here, we have expanded phase-corrected absorption mode data processing to 2D mass spectra regardless of size and frequency range. We have applied phase-corrected absorption mode 2D MS to top-down analysis of variously oxidized ubiquitin proteoforms generated by fast photochemical oxidation of proteins (FPOP) and to an extract of ergot alkaloids. We show that phase-corrected absorption mode data processing significantly improves both the SNR and the resolving power of the 2D mass spectrum compared to standard magnitude mode in terms of sequence coverage in top-down proteomics, as well as the accuracy of precursor-fragment correlation in metabolomics.

Journal of the American Society for Mass SpectrometryVol. 37(5)
Centre National de la Recherche Scientifique (FR), Inserm (FR), Universität Innsbruck (AT), Charles University (CZ), Institut de génétique et de biologie moléculaire et cellulaire (FR), Institute of Microbiology (BY), Université de Rouen Normandie (FR), Institut National des Sciences Appliquées Rouen Normandie (FR)
European Commission, Ministerstvo Školství, Mládeže a Tělovýchovy, Grantová Agentura České Republiky, Austrian Science Fund, European Regional Development Fund, Mikrobiologický Ústav, Akademie Věd České Republiky, H2020 European Institute of Innovation and Technology, H2020 Marie Skłodowska-Curie Actions
Openalex Percentile: Top 17%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Absorption Mode Broadband 2D MS for Proteomics and Metabolomics · Journal of the American Society for Mass Spectrometry (2026) | TGRS Research Map | TGRS