Novel directional detector for radioactive material search and monitoring

A detector which in addition to automatic radiation alarming and gamma-ray spectroscopy enables directional sensing for fixed, relocatable, and vehicle-mounted detection systems, is demonstrated. A robust and reliable directional sensing relies on inter-detector shadowing effect of attached asymmetric NaI(Tl) and CsI(Na) scintillators. The scintillator package is connected to a single photomultiplier tube. Demonstrated directional sensing is based on background-subtracted NaI(Tl) and CsI(Na) total counts. When a Cs-137 source is positioned in front of the NaI(Tl) detector at 0o, the NaI(Tl)/CsI(Na) total count ratio is 1.238(9). At 90o, 180o, and 270o, the ratios are 1.000(7), 0.623(6), and 0.743(6), respectively. Scintillator crystal asymmetry causes the observed difference in ratios between 90o and 270o. The differences can be further increased by enlarging the sizes and/or modifying the shapes of the asymmetric phoswich crystals. This ratio difference, combined with the time behavior of the total counts, forms the basis of directional sensing. Compact single-channel digital nuclear electronics is used for the instrument’s signal processing. Demonstrated technology enables the development of user-friendly and highly integrated detection systems with extended performance.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-27
DOI
https://doi.org/10.1038/s41598-026-49436-9
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel directional detector for radioactive material search and monitoring

Kari Peräjärvi, Ville Bogdanoff
Scientific Reports
Radiation Detection and Scintillator Technologies
article

Novel directional detector for radioactive material search and monitoring

Kari Peräjärvi, Ville Bogdanoff
article en

Abstract

A detector which in addition to automatic radiation alarming and gamma-ray spectroscopy enables directional sensing for fixed, relocatable, and vehicle-mounted detection systems, is demonstrated. A robust and reliable directional sensing relies on inter-detector shadowing effect of attached asymmetric NaI(Tl) and CsI(Na) scintillators. The scintillator package is connected to a single photomultiplier tube. Demonstrated directional sensing is based on background-subtracted NaI(Tl) and CsI(Na) total counts. When a Cs-137 source is positioned in front of the NaI(Tl) detector at 0o, the NaI(Tl)/CsI(Na) total count ratio is 1.238(9). At 90o, 180o, and 270o, the ratios are 1.000(7), 0.623(6), and 0.743(6), respectively. Scintillator crystal asymmetry causes the observed difference in ratios between 90o and 270o. The differences can be further increased by enlarging the sizes and/or modifying the shapes of the asymmetric phoswich crystals. This ratio difference, combined with the time behavior of the total counts, forms the basis of directional sensing. Compact single-channel digital nuclear electronics is used for the instrument’s signal processing. Demonstrated technology enables the development of user-friendly and highly integrated detection systems with extended performance.

Scientific Reports
Radiation and Nuclear Safety Authority (FI), University of Jyväskylä (FI)
Openalex Percentile: Top 5%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.