Faster and More Robust <scp>CK</scp> Reaction Rate Estimation at <scp>3T</scp> Using Acquisition‐Weighted <scp> <sup>31</sup> P </scp> Cardiac <scp>1D</scp> ‐ <scp>MRSI</scp> With Compartment‐Based Reconstruction

PURPOSE: ) in the human heart using phosphorus magnetic resonance spectroscopy is clinically important; however, it is limited by long acquisition times, operator subjectivity in analysis, and potential skeletal muscle contamination. This study evaluates if combining compartment-based reconstruction techniques with acquisition-weighted (AW) Triple Repetition Time Saturation Transfer (TRiST) acquisitions could overcome these challenges. METHODS: values were calculated and compared across reconstruction methods and acquisition types. RESULTS: , respectively. No significant differences were observed between FW and AW results. A significant decrease in cardiac PCr/ATP ratios was observed for SLAM and SLIM reconstructed data, suggesting decreased signal contamination from skeletal muscle. CONCLUSION: accuracy. This method provides a more robust and efficient evaluation of in vivo cardiac metabolism.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-04-26
DOI
https://doi.org/10.1002/mrm.70408
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Faster and More Robust CK Reaction Rate Estimation at 3T Using Acquisition‐Weighted 31 P Cardiac 1D ‐ MRSI With Compartment‐Based Reconstruction

Damian J. Tyler, Roshan Xavier, Ferenc E. Mózes, Ladislav Valkovič et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Faster and More Robust CK Reaction Rate Estimation at 3T Using Acquisition‐Weighted 31 P Cardiac 1D ‐ MRSI With Compartment‐Based Reconstruction

Damian J. Tyler, Roshan Xavier, Ferenc E. Mózes, Ladislav Valkovič, William Watson, Aaron Axford, Oliver J. Rider, Andrew C. Tyler, Iveta Pajanová
article en

Abstract

PURPOSE: ) in the human heart using phosphorus magnetic resonance spectroscopy is clinically important; however, it is limited by long acquisition times, operator subjectivity in analysis, and potential skeletal muscle contamination. This study evaluates if combining compartment-based reconstruction techniques with acquisition-weighted (AW) Triple Repetition Time Saturation Transfer (TRiST) acquisitions could overcome these challenges. METHODS: values were calculated and compared across reconstruction methods and acquisition types. RESULTS: , respectively. No significant differences were observed between FW and AW results. A significant decrease in cardiac PCr/ATP ratios was observed for SLAM and SLIM reconstructed data, suggesting decreased signal contamination from skeletal muscle. CONCLUSION: accuracy. This method provides a more robust and efficient evaluation of in vivo cardiac metabolism.

Magnetic Resonance in Medicine
Slovak University of Technology in Bratislava (SK), Slovak Academy of Sciences (SK), University of Cambridge (GB), Manchester Academic Health Science Centre (GB), University of Oxford (GB), Cambridge School (PT), Bridge University (SS), Institute of Measurement Science of the Slovak Academy of Sciences (SK), Oxford Centre for Diabetes, Endocrinology and Metabolism (GB), Oxford Centre for Mission Studies (GB)
Agentúra na Podporu Výskumu a Vývoja
Openalex Percentile: Top 9%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.