Perbedaan Hasil Uji Ultrasonic Pulse Velocity (UPV) Beton pada Mode Frekuensi Auto dan 50x

ABSTRACT.Ultrasonic Pulse Velocity (UPV) is a widely used non-destructive testing method for evaluating concrete, rock, and building structures by measuring the propagation velocity of longitudinal ultrasonic waves through concrete. UPV instruments are equipped with several operational parameters, including frequency, voltage, and signal transmission from the transmitter to the receiver, each of which influences measurement performance. This study aims to evaluate and compare UPV wave velocity readings obtained under various frequency settings available in the UPV system at a constant voltage supply. The experimental program consisted of material and equipment preparation, concrete mix design, fabrication of normal concrete specimens, curing, UPV testing, and data analysis. Concrete block specimens with a travel path length of 0.498 m were tested at a constant voltage of 220 V using Rx/Tx frequency variations of 24, 37, 54, 82, 150, 200, 220, 250, and 500 kHz. Signal strength was adjusted using Rx Gain AUTO and 50X settings. The test results were statistically analyzed using analysis of variance (ANOVA) to assess the stability and efficiency of each configuration. The results indicate that the Rx Gain AUTO setting provides the most stable measurements and the highest testing efficiency, making it a practical technical reference for UPV instrument calibration prior to testing. The measured UPV values ranged from approximately 5600 to 5700 m/s, indicating good material homogeneity and effective ultrasonic wave transmission within the concrete specimens.ABSTRAK. UPV (Ultrasonic Pulse Velocity) merupakan salah satu alat uji non destructive pada beton, batuan serta struktur bangunan dengan sistim kerja alat dengan memanfaatkan pancaran gelombang ultrasonik untuk menetukan kecepatan rambat gelombang longitudinal pada beton. Fitur pada alat UPV mempunyai beragam indikator antara lain: frekuensi, tegangan, kecepatan pengiriman data dari transmitter ke penerima (received) tentu saja memiliki fungsi yang beragam pula. Tujuan penelitian ini adalah membandingkan hasil pembacaan rambat gelombang ultrasonic pada alat UPV dengan variasi frekuensi yang terdapat pada fitur/menu UPV pada suplai tegangan 250V. Dari hasil penelitian ini diharapkan dapat memberikan edukasi tentang penggunaan kinerja alat laboratorium secara optimal serta menunjang pembelajaran bagi teknisi, mahasiswa dan dosen dalam mendukung penelitian serta pengabdian masyarakat. Metode penelitian ini meliputi persiapan bahan dan alat, perencanaan proporsi campuran beton, pembuatan sampel beton normal, perawatan beton, pengujian sampel dengan alat UPV dan pembahasan. Hasil Analisa pengujian dari benda uji blok beton dengan Panjang lintasan 0,498 meter, Tegangan tetap 220V dengan variasi frekuensi Rx/Tx 24 KHz, 37 KHz, 54 KHz, 82 KHz, 150 KHz, 200 KHz, 220 KHz, 250 KHz, dan 500 KHz dengan pengaturan kekuatan sinyal: Rx gain AUTO dan , 50X, Hasil Analisa ANOVA menyimpulkan bahwa nilai paling stabil dan efisiensi pengukuran terbaik pada Rx Gain AUTO sehingga bisa dijadikan acuan teknis penyetingan alat UPV sebelum digunakan. Hasil pembacaan rambat gelombang alat UPV pada kisaran (± 5600–5700) hal ini menunjukkan sifat homogenitas material dan kualitas transmisi gelombang yang baik.

Authors

Publication Details

Journal
Indonesian Journal of Laboratory
Published
2026-04-28
DOI
https://doi.org/10.22146/ijl.v9i1.115903
Primary Topic
Geotechnical and construction materials studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perbedaan Hasil Uji Ultrasonic Pulse Velocity (UPV) Beton pada Mode Frekuensi Auto dan 50x

Daru Salam, Muchamad Amirul Yachya
Indonesian Journal of Laboratory
Geotechnical and construction materials studies
article

Perbedaan Hasil Uji Ultrasonic Pulse Velocity (UPV) Beton pada Mode Frekuensi Auto dan 50x

Daru Salam, Muchamad Amirul Yachya
article en

Abstract

ABSTRACT.Ultrasonic Pulse Velocity (UPV) is a widely used non-destructive testing method for evaluating concrete, rock, and building structures by measuring the propagation velocity of longitudinal ultrasonic waves through concrete. UPV instruments are equipped with several operational parameters, including frequency, voltage, and signal transmission from the transmitter to the receiver, each of which influences measurement performance. This study aims to evaluate and compare UPV wave velocity readings obtained under various frequency settings available in the UPV system at a constant voltage supply. The experimental program consisted of material and equipment preparation, concrete mix design, fabrication of normal concrete specimens, curing, UPV testing, and data analysis. Concrete block specimens with a travel path length of 0.498 m were tested at a constant voltage of 220 V using Rx/Tx frequency variations of 24, 37, 54, 82, 150, 200, 220, 250, and 500 kHz. Signal strength was adjusted using Rx Gain AUTO and 50X settings. The test results were statistically analyzed using analysis of variance (ANOVA) to assess the stability and efficiency of each configuration. The results indicate that the Rx Gain AUTO setting provides the most stable measurements and the highest testing efficiency, making it a practical technical reference for UPV instrument calibration prior to testing. The measured UPV values ranged from approximately 5600 to 5700 m/s, indicating good material homogeneity and effective ultrasonic wave transmission within the concrete specimens.ABSTRAK. UPV (Ultrasonic Pulse Velocity) merupakan salah satu alat uji non destructive pada beton, batuan serta struktur bangunan dengan sistim kerja alat dengan memanfaatkan pancaran gelombang ultrasonik untuk menetukan kecepatan rambat gelombang longitudinal pada beton. Fitur pada alat UPV mempunyai beragam indikator antara lain: frekuensi, tegangan, kecepatan pengiriman data dari transmitter ke penerima (received) tentu saja memiliki fungsi yang beragam pula. Tujuan penelitian ini adalah membandingkan hasil pembacaan rambat gelombang ultrasonic pada alat UPV dengan variasi frekuensi yang terdapat pada fitur/menu UPV pada suplai tegangan 250V. Dari hasil penelitian ini diharapkan dapat memberikan edukasi tentang penggunaan kinerja alat laboratorium secara optimal serta menunjang pembelajaran bagi teknisi, mahasiswa dan dosen dalam mendukung penelitian serta pengabdian masyarakat. Metode penelitian ini meliputi persiapan bahan dan alat, perencanaan proporsi campuran beton, pembuatan sampel beton normal, perawatan beton, pengujian sampel dengan alat UPV dan pembahasan. Hasil Analisa pengujian dari benda uji blok beton dengan Panjang lintasan 0,498 meter, Tegangan tetap 220V dengan variasi frekuensi Rx/Tx 24 KHz, 37 KHz, 54 KHz, 82 KHz, 150 KHz, 200 KHz, 220 KHz, 250 KHz, dan 500 KHz dengan pengaturan kekuatan sinyal: Rx gain AUTO dan , 50X, Hasil Analisa ANOVA menyimpulkan bahwa nilai paling stabil dan efisiensi pengukuran terbaik pada Rx Gain AUTO sehingga bisa dijadikan acuan teknis penyetingan alat UPV sebelum digunakan. Hasil pembacaan rambat gelombang alat UPV pada kisaran (± 5600–5700) hal ini menunjukkan sifat homogenitas material dan kualitas transmisi gelombang yang baik.

Indonesian Journal of LaboratoryVol. 9(1)
Sustainable cities and communities
Openalex Percentile: Top 7%
Geotechnical and construction materials studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.