Heat Transfer in an Asymmetric Trapezoidal Duct with Angled Rib Turbulators

Abstract Heat transfer characteristics in a turbine-representative trapezoidal duct with angled rib turbulators were investigated over Reynolds numbers of 20,000–60,000. Previous studies have examined non-rectangular ribbed passages, however, simultaneous two-wall, wall-resolved heat transfer datasets that enable direct wall-to-wall comparison in an asymmetric cross-section remain relatively limited. To address this gap, wall-resolved Sherwood number contours were obtained using the naphthalene sublimation method on two ribbed walls, referred to as the vertical and lean walls, which serve as pressure side and suction side analogs. The measured contours show typical angled rib behavior, including rib-imposed streamwise periodicity and pronounced spanwise non-uniformity in Sherwood number. Despite the geometrically asymmetric trapezoidal cross-section, the vertical and lean walls exhibit nearly identical heat transfer levels within experimental uncertainty, with a maximum difference of 3.4 % in area-averaged Sherwood number. Complementary simulations were used to relate the spanwise redistribution to cross-sectional secondary flow structures and to explain the observed wall-to-wall behavior through comparable secondary flow intensity near the two ribbed walls. The present results also provide a direct comparison showing that the area-averaged heat transfer enhancement in asymmetric trapezoidal ribbed passage is slightly lower to that reported for symmetric rectangular ribbed channels under matched Reynolds number and aspect ratio. Overall, the simultaneous two-wall dataset and the flow structure interpretation provide a practical reference for angled rib heat transfer behavior in non-rectangular passages relevant to trailing edge cooling design.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Science and Engineering Applications
Published
2026-04-27
DOI
https://doi.org/10.1115/1.4071796
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Transfer in an Asymmetric Trapezoidal Duct with Angled Rib Turbulators

Jeonghun Heo, Gyeongryun Kim, Hyung Hee Cho, Hee Jae Lee et al.
Journal of Thermal Science and Engineering Applications
Heat Transfer Mechanisms
article

Heat Transfer in an Asymmetric Trapezoidal Duct with Angled Rib Turbulators

Jeonghun Heo, Gyeongryun Kim, Hyung Hee Cho, Hee Jae Lee, Changyong Lee
article en

Abstract

Abstract Heat transfer characteristics in a turbine-representative trapezoidal duct with angled rib turbulators were investigated over Reynolds numbers of 20,000–60,000. Previous studies have examined non-rectangular ribbed passages, however, simultaneous two-wall, wall-resolved heat transfer datasets that enable direct wall-to-wall comparison in an asymmetric cross-section remain relatively limited. To address this gap, wall-resolved Sherwood number contours were obtained using the naphthalene sublimation method on two ribbed walls, referred to as the vertical and lean walls, which serve as pressure side and suction side analogs. The measured contours show typical angled rib behavior, including rib-imposed streamwise periodicity and pronounced spanwise non-uniformity in Sherwood number. Despite the geometrically asymmetric trapezoidal cross-section, the vertical and lean walls exhibit nearly identical heat transfer levels within experimental uncertainty, with a maximum difference of 3.4 % in area-averaged Sherwood number. Complementary simulations were used to relate the spanwise redistribution to cross-sectional secondary flow structures and to explain the observed wall-to-wall behavior through comparable secondary flow intensity near the two ribbed walls. The present results also provide a direct comparison showing that the area-averaged heat transfer enhancement in asymmetric trapezoidal ribbed passage is slightly lower to that reported for symmetric rectangular ribbed channels under matched Reynolds number and aspect ratio. Overall, the simultaneous two-wall dataset and the flow structure interpretation provide a practical reference for angled rib heat transfer behavior in non-rectangular passages relevant to trailing edge cooling design.

Journal of Thermal Science and Engineering Applications
Gachon University (KR), Yonsei University (KR)
Doosan Heavy Industries and Construction
Affordable and clean energy
Openalex Percentile: Top 7%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Heat Transfer in an Asymmetric Trapezoidal Duct with Angled Rib Turbulators — Jeonghun Heo, Gyeongryun Kim, et al. · Journal of Thermal Science and Engineering Applications (2026) | TGRS Research Map | TGRS