Self-Assembled DNA Nanoladder-Based Electrochemical Biosensor for Rapid and Sensitive Detection of Bladder Tumor-Related miRNA in Urine

Early diagnosis is critical for improving the survival rate of patients with bladder cancer (BCa), and urinary biomarker detection offers a promising noninvasive approach for early BCa screening. However, the typically low abundance of these biomarkers in urine samples remains a major challenge for conventional detection methods. To address this, we developed a self-assembled DNA nanoladder-based electrochemical biosensor for the rapid and sensitive detection of miR-126 in urine. Upon introduction of target miR-126, it hybridizes with the C/W duplex, leading to the production of single C strands on the electrode surface. This single-stranded C strand then triggers the hybridization chain reaction (HCR) of the DNA nanoladder (DNL), resulting in the formation of elongated ladder-like nicked double-stranded DNA polymers on the electrode surface. These dsDNA structures subsequently capture a large number of RuHex molecules through electrostatic interactions, generating a significantly enhanced differential pulse voltammetry (DPV) signal. Benefiting from the high signal amplification efficiency and fast kinetics of the DNA nanoladder (DNL), the developed electrochemical biosensor enables the sensitive detection of miR-126 with a detection limit of 59.0 aM, a linear detection range of 5 fM to 1 nM, and a total detection time of less than 30 min. In a cohort of 15 cancer patients and 10 negative control samples, the constructed DNL-based biosensors could detect bladder cancer with 93.3% sensitivity, 100% specificity, and an accuracy of 96.0%. The designed DNA nanoladder electrochemical biosensor provides a new strategy to realize accurate detection of complex clinical samples to achieve early cancer diagnostics.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-04-27
DOI
https://doi.org/10.1021/acs.analchem.6c01040
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Self-Assembled DNA Nanoladder-Based Electrochemical Biosensor for Rapid and Sensitive Detection of Bladder Tumor-Related miRNA in Urine

Jin Lin Huang, Shuangquan Liu, Yi-Xiang Wang, Huanhuan Sun et al.
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
article

Self-Assembled DNA Nanoladder-Based Electrochemical Biosensor for Rapid and Sensitive Detection of Bladder Tumor-Related miRNA in Urine

Jin Lin Huang, Shuangquan Liu, Yi-Xiang Wang, Huanhuan Sun, Yajun Wang, Weitao Yan, Jingping Liu, Yuyu Tan
article en

Abstract

Early diagnosis is critical for improving the survival rate of patients with bladder cancer (BCa), and urinary biomarker detection offers a promising noninvasive approach for early BCa screening. However, the typically low abundance of these biomarkers in urine samples remains a major challenge for conventional detection methods. To address this, we developed a self-assembled DNA nanoladder-based electrochemical biosensor for the rapid and sensitive detection of miR-126 in urine. Upon introduction of target miR-126, it hybridizes with the C/W duplex, leading to the production of single C strands on the electrode surface. This single-stranded C strand then triggers the hybridization chain reaction (HCR) of the DNA nanoladder (DNL), resulting in the formation of elongated ladder-like nicked double-stranded DNA polymers on the electrode surface. These dsDNA structures subsequently capture a large number of RuHex molecules through electrostatic interactions, generating a significantly enhanced differential pulse voltammetry (DPV) signal. Benefiting from the high signal amplification efficiency and fast kinetics of the DNA nanoladder (DNL), the developed electrochemical biosensor enables the sensitive detection of miR-126 with a detection limit of 59.0 aM, a linear detection range of 5 fM to 1 nM, and a total detection time of less than 30 min. In a cohort of 15 cancer patients and 10 negative control samples, the constructed DNL-based biosensors could detect bladder cancer with 93.3% sensitivity, 100% specificity, and an accuracy of 96.0%. The designed DNA nanoladder electrochemical biosensor provides a new strategy to realize accurate detection of complex clinical samples to achieve early cancer diagnostics.

Analytical Chemistry
Hunan University (CN), Hunan First Normal University (CN), University of South China (CN)
Openalex Percentile: Top 8%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.