MRI-based CFD simulations of transient blood flow in compliant aortas using the LDDMM framework

BACKGROUND: Traditional CFD analyses often rely on static (rigid) vascular geometries, which neglect the physiologically relevant motion of the aortic wall. This simplification can lead to inaccuracies in estimating key hemodynamic biomarkers, such as wall shear stress (WSS) and oscillatory shear index (OSI). METHODS: This study introduces the Large Deformation Diffeomorphic Metric Mapping (LDDMM) method to enable computationally efficient simulations of transient blood flow in compliant, subject- and patient-specific aortas derived from 4D Flow MRI data. The proposed framework simplifies CFD pre-processing, improves morphing accuracy, and enables physiologically realistic motion of the thoracic aorta, including its side-branches. The method was applied to two aortic geometries: a healthy case (HC) and a case with thoracic aortic aneurysm (TAA) located in the ascending region. RESULTS: The results were compared with those obtained from fixed aortic geometries extracted at peak systole. Hemodynamic biomarkers showed significant differences between static and moving geometries. For the healthy case (HC), the differences were 18% for the time-averaged wall shear stress (TAWSS) and 46% for the oscillatory shear index (OSI). For the thoracic aorta aneurysm (TAA) case, the corresponding values were 14% and 47%, respectively. CONCLUSION: These findings highlight the importance of incorporating aortic wall motion in hemodynamic simulations. The developed LDDMM-based framework can be readily extended to other imaging modalities, such as ultrasound or computed tomography, and is recommended for future CFD analyses of compliant aortas.

Authors

Institutions

Publication Details

Journal
Computer Methods and Programs in Biomedicine
Published
2026-04-27
DOI
https://doi.org/10.1016/j.cmpb.2026.109385
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MRI-based CFD simulations of transient blood flow in compliant aortas using the LDDMM framework

Saša Kenjereš, Jos J.M. Westenberg, Hildo J. Lamb, Daiqi Lin
Computer Methods and Programs in Biomedicine
Aortic Disease and Treatment Approaches
article

MRI-based CFD simulations of transient blood flow in compliant aortas using the LDDMM framework

Saša Kenjereš, Jos J.M. Westenberg, Hildo J. Lamb, Daiqi Lin
article en

Abstract

BACKGROUND: Traditional CFD analyses often rely on static (rigid) vascular geometries, which neglect the physiologically relevant motion of the aortic wall. This simplification can lead to inaccuracies in estimating key hemodynamic biomarkers, such as wall shear stress (WSS) and oscillatory shear index (OSI). METHODS: This study introduces the Large Deformation Diffeomorphic Metric Mapping (LDDMM) method to enable computationally efficient simulations of transient blood flow in compliant, subject- and patient-specific aortas derived from 4D Flow MRI data. The proposed framework simplifies CFD pre-processing, improves morphing accuracy, and enables physiologically realistic motion of the thoracic aorta, including its side-branches. The method was applied to two aortic geometries: a healthy case (HC) and a case with thoracic aortic aneurysm (TAA) located in the ascending region. RESULTS: The results were compared with those obtained from fixed aortic geometries extracted at peak systole. Hemodynamic biomarkers showed significant differences between static and moving geometries. For the healthy case (HC), the differences were 18% for the time-averaged wall shear stress (TAWSS) and 46% for the oscillatory shear index (OSI). For the thoracic aorta aneurysm (TAA) case, the corresponding values were 14% and 47%, respectively. CONCLUSION: These findings highlight the importance of incorporating aortic wall motion in hemodynamic simulations. The developed LDDMM-based framework can be readily extended to other imaging modalities, such as ultrasound or computed tomography, and is recommended for future CFD analyses of compliant aortas.

Computer Methods and Programs in BiomedicineVol. 282
Leiden University Medical Center (NL), J.M. Burgerscentrum (NL), Delft University of Technology (NL)
Hartstichting, China Scholarship Council
Openalex Percentile: Top 12%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.