Efficacy and Safety of CorVad System in Coronary Intervention for Complex High‐Risk and Indicated Patients

BACKGROUND: Due to the heightened risks and complications associated with percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) in complex high-risk and indicated patients (CHIPs), percutaneous ventricular assist system during PCI might offer a novel alternative. AIMS: We aimed to evaluate the efficacy and safety of the CorVad percutaneous ventricular assist system in CHIPs. METHODS: One hundred and eighteen CHIPs with left ventricular ejection fraction (LVEF) ≤ 40% were enrolled for CorVad support during elective PCI. The primary endpoint was the incidence of major adverse cardiovascular and cerebrovascular events (MACCE) including death, new myocardial infarction, stroke, and target vessel revascularization at 30 days. Performance goal (PG) was set at 22.5%. Additionally, patients underwent CABG in Fuwai Hospital with LVEF ≤ 40% were selected as historical controls. RESULTS: In the intention to treat (ITT) cohort, there were five MACCE (4.2%, 95% CI 1.4%-9.6%) within 30 days, achieving the prespecified PG. The CorVad system was successfully implanted in all patients. Compared with baseline, the LVEF had a significant increase in 48 h (30.95 ± 4.84% vs. 35.96 ± 5.84%, p < 0.001) and 30 days after PCI (30.95 ± 4.84% vs. 39.78 ± 7.82%, p < 0.001). No patient had evidence of hemolysis after PCI. Compared with CABG historical controls, there were no significant differences in the incidence of MACCE at 30 days (after propensity score matching [PSM]: 3.8% vs. 1.3%, p = 0.341) and 90 days (after PSM: 3.8% vs. 1.3%, p = 0.307). CONCLUSIONS: The CorVad percutaneous ventricular assist system is safe and effective in assisting CHIPs-PCI.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-04-26
DOI
https://doi.org/10.1002/ccd.70617
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and Safety of CorVad System in Coronary Intervention for Complex High‐Risk and Indicated Patients

Shunzhou Yu, Jianfang Luo, Yuquan He, Yan Dong et al.
Catheterization and Cardiovascular Interventions
Mechanical Circulatory Support Devices
article

Efficacy and Safety of CorVad System in Coronary Intervention for Complex High‐Risk and Indicated Patients

Shunzhou Yu, Jianfang Luo, Yuquan He, Yan Dong, Hongwei Pan, Shizhang Chen, Jun Jiang, W E I Feng, Kefei Dou, Xianqiang Wang, Guofeng Gao, Bowen Li, Qi Zhang, Yu Cao, Ming Bai, Yan Li, Ling Tao
article en

Abstract

BACKGROUND: Due to the heightened risks and complications associated with percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) in complex high-risk and indicated patients (CHIPs), percutaneous ventricular assist system during PCI might offer a novel alternative. AIMS: We aimed to evaluate the efficacy and safety of the CorVad percutaneous ventricular assist system in CHIPs. METHODS: One hundred and eighteen CHIPs with left ventricular ejection fraction (LVEF) ≤ 40% were enrolled for CorVad support during elective PCI. The primary endpoint was the incidence of major adverse cardiovascular and cerebrovascular events (MACCE) including death, new myocardial infarction, stroke, and target vessel revascularization at 30 days. Performance goal (PG) was set at 22.5%. Additionally, patients underwent CABG in Fuwai Hospital with LVEF ≤ 40% were selected as historical controls. RESULTS: In the intention to treat (ITT) cohort, there were five MACCE (4.2%, 95% CI 1.4%-9.6%) within 30 days, achieving the prespecified PG. The CorVad system was successfully implanted in all patients. Compared with baseline, the LVEF had a significant increase in 48 h (30.95 ± 4.84% vs. 35.96 ± 5.84%, p < 0.001) and 30 days after PCI (30.95 ± 4.84% vs. 39.78 ± 7.82%, p < 0.001). No patient had evidence of hemolysis after PCI. Compared with CABG historical controls, there were no significant differences in the incidence of MACCE at 30 days (after propensity score matching [PSM]: 3.8% vs. 1.3%, p = 0.341) and 90 days (after PSM: 3.8% vs. 1.3%, p = 0.307). CONCLUSIONS: The CorVad percutaneous ventricular assist system is safe and effective in assisting CHIPs-PCI.

Catheterization and Cardiovascular Interventions
Union Hospital (HK), Central South University (CN), Hunan Normal University (CN), Jilin University (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), National Clinical Research Center for Digestive Diseases (CN), Shanghai East Hospital (CN), Guangdong Academy of Medical Sciences (CN), Tang Du Hospital (CN), Third Xiangya Hospital (CN), Second Affiliated Hospital of Zhejiang University (CN), Xijing Hospital (CN), Shenzhen Genoimmune Medical Institute (CN), Fu Wai Hospital (CN), First Hospital of Lanzhou University (CN), State Key Laboratory of Cardiovascular Disease, Lanzhou University (CN)
Good health and well-being
Openalex Percentile: Top 7%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.