The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images

To investigate whether virtual unenhanced (VUE) images generated from spectral CT using the rapid kVp switching technique can serve as a substitute for true unenhanced (TUE) images in the assessment of acute pancreatitis (AP). This retrospective study included 90 patients diagnosed with AP according to the Revised Atlanta Classification who underwent unenhanced non-spectral CT scan and dual-phase spectral CT scans of the abdomen. VUE images for the arterial (AP-VUE) and venous phases (VP-VUE) were reconstructed using material decomposition techniques. Objective and subjective assessments were conducted on TUE, AP-VUE, and VP-VUE images. The objective evaluation included CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The subjective evaluation was performed by three readers independently and assessed image quality, lesion identification, severity grading of pancreatitis, and diagnostic confidence. CT attenuations differences between the TUE and VUE images were not significant for AP lesion (P = 0.110 (Pancreatitis) & 0.052 (Peripancreatic effusion)), with over 76.67% of anatomical regions showing differences within 10 HU. Compared with VP-VUE and AP-VUE images, TUE images demonstrated higher SNR and CNR overall. Diagnostic confidence scores were comparable across TUE, AP-VUE, and VP-VUE (confidence scores from 5(4, 5) to 5(5, 5), P from 0.439 to 1.000) and the diagnostic conclusions showed no significant differences as well (P > 0.05). The Balthazar CT grading system (A–E) demonstrated high concordance (Intraclass correlation coefficients > 0.8) across all image types, with no difference in AP severity assessment (P > 0.05). The diagnostic value of VUE images in AP is comparable to that of TUE images, suggesting that VUE images can serve as an alternative to reduce radiation exposure.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-04-27
DOI
https://doi.org/10.1186/s12880-026-02361-9
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images

Houzhang Sun, Haifang Yu, Hongyan Wang, Chengjin Fan et al.
BMC Medical Imaging
Advanced X-ray and CT Imaging
article

The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images

Houzhang Sun, Haifang Yu, Hongyan Wang, Chengjin Fan, Yunjun Yang, Liaoyi Lin, Aiyun Sun
article en

Abstract

To investigate whether virtual unenhanced (VUE) images generated from spectral CT using the rapid kVp switching technique can serve as a substitute for true unenhanced (TUE) images in the assessment of acute pancreatitis (AP). This retrospective study included 90 patients diagnosed with AP according to the Revised Atlanta Classification who underwent unenhanced non-spectral CT scan and dual-phase spectral CT scans of the abdomen. VUE images for the arterial (AP-VUE) and venous phases (VP-VUE) were reconstructed using material decomposition techniques. Objective and subjective assessments were conducted on TUE, AP-VUE, and VP-VUE images. The objective evaluation included CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The subjective evaluation was performed by three readers independently and assessed image quality, lesion identification, severity grading of pancreatitis, and diagnostic confidence. CT attenuations differences between the TUE and VUE images were not significant for AP lesion (P = 0.110 (Pancreatitis) & 0.052 (Peripancreatic effusion)), with over 76.67% of anatomical regions showing differences within 10 HU. Compared with VP-VUE and AP-VUE images, TUE images demonstrated higher SNR and CNR overall. Diagnostic confidence scores were comparable across TUE, AP-VUE, and VP-VUE (confidence scores from 5(4, 5) to 5(5, 5), P from 0.439 to 1.000) and the diagnostic conclusions showed no significant differences as well (P > 0.05). The Balthazar CT grading system (A–E) demonstrated high concordance (Intraclass correlation coefficients > 0.8) across all image types, with no difference in AP severity assessment (P > 0.05). The diagnostic value of VUE images in AP is comparable to that of TUE images, suggesting that VUE images can serve as an alternative to reduce radiation exposure.

BMC Medical ImagingVol. 26(1)
Wenzhou Medical University (CN), First Affiliated Hospital of Wenzhou Medical University (CN), United Imaging Healthcare (China) (CN)
Wenzhou Medical University
Good health and well-being
Openalex Percentile: Top 15%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.