Calibration of the Fe–Ir redox sensor at high pressure and the oxygen fugacity of laser heated diamond anvil cell experiments

The Fe–Ir binary alloy has been calibrated up to 100 GPa as a part of a thermodynamic model (oxygen fugacity $${(f}_{{\text{O}}_{2}})$$ sensor system) to monitor the redox conditions during high–pressure and high–temperature petrology experiments. The existing Fe–Ir activity–composition relations at 1 bar and ~ 473–2873 K have been updated by including the pressure dependence on the activity–composition relations. We calibrated the volume dependent interaction parameter $${W}^{V}$$ up to 61 GPa and extrapolated the Margules activity model (i.e., $${W}_{\text{Fe}-\text{Ir}}^{G}$$ and $${W}_{\text{Ir}-\text{Fe}}^{G}$$ ) up to 100 GPa by combining the experimentally determined compressibility and compositional data of the alloy, with those of the end member phases in a thermodynamic model. We apply the newly calibrated redox sensor to oxygen fugacity determination during laser heated diamond anvil cell (LHDAC) experiments. In situ LHDAC experiments were performed up to ~ 61 GPa and ~ 2000 K. We tracked the $${f}_{{\text{O}}_{2}}$$ conditions in the DAC by reacting the powdered mixture during laser heating to form a Fe–Ir alloy (sliding redox sensor) and using high–resolution synchrotron Mössbauer Source spectroscopy, powder X–ray diffraction, X–ray absorption near–edge structure spectroscopy, analytical transmission electron microscopy, and chemical analyses down to the nanoscale. The inferred oxygen fugacities measured at the specific P–T conditions of the experiments are ~ 1 log unit below the iron–wüstite buffer, which is lower than estimates obtained with the existing model and compared to multi anvil experiments performed with the same starting mixture at similar P–T conditions.

Authors

Institutions

Publication Details

Journal
Contributions to Mineralogy and Petrology
Published
2026-04-28
DOI
https://doi.org/10.1007/s00410-026-02314-z
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of the Fe–Ir redox sensor at high pressure and the oxygen fugacity of laser heated diamond anvil cell experiments

T. Fedotenko, Nοbuyοshi Miyajima, D.J. Frost, C. Melai et al.
Contributions to Mineralogy and Petrology
Diamond and Carbon-based Materials Research
article

Calibration of the Fe–Ir redox sensor at high pressure and the oxygen fugacity of laser heated diamond anvil cell experiments

T. Fedotenko, Nοbuyοshi Miyajima, D.J. Frost, C. Melai, S. Dominijanni, C. McCammon, G. Aprilis, V. Svitlyk, A. D. Rosa, Z.Y. Liu, A. Chumakov, S. Khandarkhaeva, S. Chariton, M. Hanfland, I. Koemets, L. S. Dubrovinsky, V. Cerantola, E. Koemets
article en

Abstract

The Fe–Ir binary alloy has been calibrated up to 100 GPa as a part of a thermodynamic model (oxygen fugacity $${(f}_{{\text{O}}_{2}})$$ sensor system) to monitor the redox conditions during high–pressure and high–temperature petrology experiments. The existing Fe–Ir activity–composition relations at 1 bar and ~ 473–2873 K have been updated by including the pressure dependence on the activity–composition relations. We calibrated the volume dependent interaction parameter $${W}^{V}$$ up to 61 GPa and extrapolated the Margules activity model (i.e., $${W}_{\text{Fe}-\text{Ir}}^{G}$$ and $${W}_{\text{Ir}-\text{Fe}}^{G}$$ ) up to 100 GPa by combining the experimentally determined compressibility and compositional data of the alloy, with those of the end member phases in a thermodynamic model. We apply the newly calibrated redox sensor to oxygen fugacity determination during laser heated diamond anvil cell (LHDAC) experiments. In situ LHDAC experiments were performed up to ~ 61 GPa and ~ 2000 K. We tracked the $${f}_{{\text{O}}_{2}}$$ conditions in the DAC by reacting the powdered mixture during laser heating to form a Fe–Ir alloy (sliding redox sensor) and using high–resolution synchrotron Mössbauer Source spectroscopy, powder X–ray diffraction, X–ray absorption near–edge structure spectroscopy, analytical transmission electron microscopy, and chemical analyses down to the nanoscale. The inferred oxygen fugacities measured at the specific P–T conditions of the experiments are ~ 1 log unit below the iron–wüstite buffer, which is lower than estimates obtained with the existing model and compared to multi anvil experiments performed with the same starting mixture at similar P–T conditions.

Contributions to Mineralogy and PetrologyVol. 181(5)
Trinity College Dublin (IE), European Synchrotron Radiation Facility (FR), Diamond Light Source (GB), University of Chicago (US), University of Bayreuth (DE), University of Milano-Bicocca (IT)
Deutsche Forschungsgemeinschaft, Universität Bayreuth
Affordable and clean energy
Openalex Percentile: Top 10%
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.