Effect of Sonic Application Mode on the Microtensile Bond Strength of Two Adhesive Systems

Background: This study aimed to compare the effects of application according to manufacturers’ instructions and sonic activation on the microtensile bond strength (µTBS) to dentin of a universal adhesive system and a two-step self-etch adhesive system.Materials and Methods: Forty caries-free human molars were randomly assigned to four experimental groups (n = 10) based on adhesive system and application mode (slight rubbing or sonic activation). A universal adhesive system (Nova Compo B Plus [NC]; Imicryl, Turkey) and a two-step self-etch adhesive system (Clearfil SE Bond [SE]; Kuraray, Japan) were evaluated. Each adhesive was applied either with a slight rubbing motion, as recommended by the manufacturers, or with sonic activation. All teeth were restored with a composite resin compatible with the respective adhesive system. After storage in distilled water at 37°C for 24 hours, specimens were sectioned into stick-shaped samples with a cross-sectional area of approximately 0.9 mm². Microtensile bond strength testing was performed at a crosshead speed of 0.5 mm/min, and failure modes were assessed under a stereomicroscope. Data were analyzed using two-way ANOVA followed by Tukey’s post hoc test (α = 0.05), and failure mode distributions were evaluated using the chi-square test.Results: Adhesive failures were observed in all groups. Sonic application significantly reduced the µTBS of the universal adhesive system compared with conventional rubbing application (P < 0.05). However, sonic activation did not significantly affect the dentin bond strength of the two-step self-etch adhesive system.Conclusion: The effect of sonic application on dentin bond strength appears to be adhesive-system dependent. While sonic activation adversely affected the bonding performance of the simplified universal adhesive system, it had no significant effect on the bond strength of the two-step self-etch adhesive system.

Authors

Institutions

Publication Details

Journal
Selcuk Dental Journal
Published
2026-04-27
DOI
https://doi.org/10.15311/selcukdentj.1846738
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Sonic Application Mode on the Microtensile Bond Strength of Two Adhesive Systems

Sultan Gizem ÜLKÜ, Nimet Ünlü, Alpaslan Can Çelik
Selcuk Dental Journal
Dental materials and restorations
article

Effect of Sonic Application Mode on the Microtensile Bond Strength of Two Adhesive Systems

Sultan Gizem ÜLKÜ, Nimet Ünlü, Alpaslan Can Çelik
article en

Abstract

Background: This study aimed to compare the effects of application according to manufacturers’ instructions and sonic activation on the microtensile bond strength (µTBS) to dentin of a universal adhesive system and a two-step self-etch adhesive system.Materials and Methods: Forty caries-free human molars were randomly assigned to four experimental groups (n = 10) based on adhesive system and application mode (slight rubbing or sonic activation). A universal adhesive system (Nova Compo B Plus [NC]; Imicryl, Turkey) and a two-step self-etch adhesive system (Clearfil SE Bond [SE]; Kuraray, Japan) were evaluated. Each adhesive was applied either with a slight rubbing motion, as recommended by the manufacturers, or with sonic activation. All teeth were restored with a composite resin compatible with the respective adhesive system. After storage in distilled water at 37°C for 24 hours, specimens were sectioned into stick-shaped samples with a cross-sectional area of approximately 0.9 mm². Microtensile bond strength testing was performed at a crosshead speed of 0.5 mm/min, and failure modes were assessed under a stereomicroscope. Data were analyzed using two-way ANOVA followed by Tukey’s post hoc test (α = 0.05), and failure mode distributions were evaluated using the chi-square test.Results: Adhesive failures were observed in all groups. Sonic application significantly reduced the µTBS of the universal adhesive system compared with conventional rubbing application (P < 0.05). However, sonic activation did not significantly affect the dentin bond strength of the two-step self-etch adhesive system.Conclusion: The effect of sonic application on dentin bond strength appears to be adhesive-system dependent. While sonic activation adversely affected the bonding performance of the simplified universal adhesive system, it had no significant effect on the bond strength of the two-step self-etch adhesive system.

Selcuk Dental JournalVol. 13(1)
Selçuk University (TR)
Openalex Percentile: Top 7%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.