An Interchangeability Test Method for Developing <scp>IPG</scp> Impedance Equivalency Evidence for Cardiac Implantable Electronic Device Under <scp>MRI</scp>

PURPOSE: Patients with cardiac implantable electronic devices (CIEDs) may receive replacement device components over time, resulting in mixed-manufacturer systems that pose unknown, potentially higher risk under MRI exposure. It is not clear how to efficiently evaluate whether adding a non-original implantable pulse generator (IPG) changes the system's radiofrequency (RF)-induced heating response. This study aimed to develop a least-burdensome RF safety evaluation method for MR Conditional labeling of CIEDs. Critical parameters were characterized and demonstrated as an IPG equivalency test method that supports leveraging existing single-manufacturer MR-Conditional labeling for mixed-manufacturer systems. METHODS: ). Deposited power near the lead tip was compared for 50 Ω and open-end conditions, and lead or IPG impedances were measured at 64 and 128 MHz. RESULTS: Lead tip heating was not significantly different between original and third-party IPGs configurations (p < 0.001). RF-induced heating responses were outside of measurement uncertainty when the lead was connected with a 50 Ω resistor and some open-end conditions. The results showed that small changes in IPG impedance (< 2.5 Ω) to the lead-IPG system impedance (> 80.2 Ω) may not significantly alter RF-induced heating, remaining within measurement uncertainties. CONCLUSION: A simplified IPG impedance equivalency test has been developed to facilitate MRI access for patients with CIEDs that undergo IPG interchange. This test aids assessment of whether replacing an original IPG model with a different model may significantly increase RF-induced heating compared to the original system.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-04-26
DOI
https://doi.org/10.1002/mrm.70389
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Interchangeability Test Method for Developing IPG Impedance Equivalency Evidence for Cardiac Implantable Electronic Device Under MRI

Hongbae Jeong, A. Gordon Smith, Ananda Kumar
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

An Interchangeability Test Method for Developing IPG Impedance Equivalency Evidence for Cardiac Implantable Electronic Device Under MRI

Hongbae Jeong, A. Gordon Smith, Ananda Kumar
article en

Abstract

PURPOSE: Patients with cardiac implantable electronic devices (CIEDs) may receive replacement device components over time, resulting in mixed-manufacturer systems that pose unknown, potentially higher risk under MRI exposure. It is not clear how to efficiently evaluate whether adding a non-original implantable pulse generator (IPG) changes the system's radiofrequency (RF)-induced heating response. This study aimed to develop a least-burdensome RF safety evaluation method for MR Conditional labeling of CIEDs. Critical parameters were characterized and demonstrated as an IPG equivalency test method that supports leveraging existing single-manufacturer MR-Conditional labeling for mixed-manufacturer systems. METHODS: ). Deposited power near the lead tip was compared for 50 Ω and open-end conditions, and lead or IPG impedances were measured at 64 and 128 MHz. RESULTS: Lead tip heating was not significantly different between original and third-party IPGs configurations (p < 0.001). RF-induced heating responses were outside of measurement uncertainty when the lead was connected with a 50 Ω resistor and some open-end conditions. The results showed that small changes in IPG impedance (< 2.5 Ω) to the lead-IPG system impedance (> 80.2 Ω) may not significantly alter RF-induced heating, remaining within measurement uncertainties. CONCLUSION: A simplified IPG impedance equivalency test has been developed to facilitate MRI access for patients with CIEDs that undergo IPG interchange. This test aids assessment of whether replacing an original IPG model with a different model may significantly increase RF-induced heating compared to the original system.

Magnetic Resonance in Medicine
Center for Devices and Radiological Health (US)
Openalex Percentile: Top 6%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.