FENCE: Flexible Electric Noise Reduction Endo‐Shield for the Suppression of Electromagnetic Interference in Low‐Field MRI

Electromagnetic interference (EMI) is a significant challenge for low-field MRI systems operating without conventional Faraday-shielded rooms. This interference degrades image quality and limits deployment in space-constrained or electromagnetically noisy environments. Traditional EMI mitigation approaches include external shields, subject grounding via electrodes, or active noise cancellation requiring synchronized receive channels. These methods either limit portability, introduce patient discomfort, or demand advanced hardware. In this work, we start from the hypothesis that EMI primarily couples capacitively from the body to the RF coil. We investigated two methods of blocking capacitive coupling while preserving inductive MRI signal detection: First, we employed capacitive segmentation of the RF coil and studied its effect on EMI coupling. Second, we present FENCE(Flexible Electromagnetic Noise reduCtion Endo-shield), a novel approach blocking capacitive coupling using flexible PCB shields placed inside the RF coil. FENCE can be retrofitted to existing RF coils without significant mechanical modifications. Finite element (FE) simulations were used to estimate the expected shielding performance and the impact on RF coil losses prior to practical implementation. Testing in various scenarios then demonstrated that the combination of FENCE with segmented solenoid coils is effective against both environmental noise sources and controlled EMI. In phantom experiments, FENCE significantly improved imaging performance and reduced EMI levels to near-baseline levels with 9% reduction in coil quality factor (Q factor), showing good agreement with the predictions from the FE simulations. In vivo head imaging confirmed these results across diverse electromagnetic environments significantly improving imaging performance while showing an 18% decrease in Q factor. FENCE provides a simple method for EMI mitigation in low-field MRI, enhancing image quality while maintaining system portability and accessibility. This approach could help to expand the deployment of low-field MRI systems in low-cost point-of-care applications where conventional shielding is impractical.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-04-26
DOI
https://doi.org/10.1002/nbm.70287
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FENCE: Flexible Electric Noise Reduction Endo‐Shield for the Suppression of Electromagnetic Interference in Low‐Field MRI

Hermann Scharfetter, Martin Uecker, Julia Pfitzer
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

FENCE: Flexible Electric Noise Reduction Endo‐Shield for the Suppression of Electromagnetic Interference in Low‐Field MRI

Hermann Scharfetter, Martin Uecker, Julia Pfitzer
article en

Abstract

Electromagnetic interference (EMI) is a significant challenge for low-field MRI systems operating without conventional Faraday-shielded rooms. This interference degrades image quality and limits deployment in space-constrained or electromagnetically noisy environments. Traditional EMI mitigation approaches include external shields, subject grounding via electrodes, or active noise cancellation requiring synchronized receive channels. These methods either limit portability, introduce patient discomfort, or demand advanced hardware. In this work, we start from the hypothesis that EMI primarily couples capacitively from the body to the RF coil. We investigated two methods of blocking capacitive coupling while preserving inductive MRI signal detection: First, we employed capacitive segmentation of the RF coil and studied its effect on EMI coupling. Second, we present FENCE(Flexible Electromagnetic Noise reduCtion Endo-shield), a novel approach blocking capacitive coupling using flexible PCB shields placed inside the RF coil. FENCE can be retrofitted to existing RF coils without significant mechanical modifications. Finite element (FE) simulations were used to estimate the expected shielding performance and the impact on RF coil losses prior to practical implementation. Testing in various scenarios then demonstrated that the combination of FENCE with segmented solenoid coils is effective against both environmental noise sources and controlled EMI. In phantom experiments, FENCE significantly improved imaging performance and reduced EMI levels to near-baseline levels with 9% reduction in coil quality factor (Q factor), showing good agreement with the predictions from the FE simulations. In vivo head imaging confirmed these results across diverse electromagnetic environments significantly improving imaging performance while showing an 18% decrease in Q factor. FENCE provides a simple method for EMI mitigation in low-field MRI, enhancing image quality while maintaining system portability and accessibility. This approach could help to expand the deployment of low-field MRI systems in low-cost point-of-care applications where conventional shielding is impractical.

NMR in BiomedicineVol. 39(6)
Graz University of Technology (AT), BioTechMed-Graz (AT)
Openalex Percentile: Top 6%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.