Pulse of the Arctic: feasibility of long-term physiological monitoring of polar bears using implantable heart rate and temperature loggers

Abstract Background Energy expenditure shapes key biological functions in animals, including reproduction, growth, foraging, and survival. Yet quantifying energy expenditure over long periods in wildlife, especially in remote Arctic environments, remains difficult. Traditional approaches of estimating metabolic rate using heart rate (HR) measurements by external devices have substantial limitations, whereas implantable biologgers offer a promising alternative. This study assesses for the first time the feasibility of using implantable heart rate and temperature (HRT) loggers in wild adult female polar bears (Ursus maritimus) equipped with GPS collars in the Svalbard Archipelago. Results Five bears were surgically implanted with HRT devices that recorded HR and body temperature every 15 min for more than a year, along with short (4 s) and long (10 s) electrocardiograms (ECG) every 6 h and 18 h, respectively. The females were tracked using GPS collars throughout the study. All implantation procedures were completed safely, and device retrieval the following year revealed no lasting health effects. The loggers performed reliably, with 82% of HR data classified as high quality. Manual validation of ECGs increased data retention by 1.7% and verified the accuracy of extreme HR values (11 to 178 BPM). Lower-quality data were generally associated with shorter ECG durations and low HR, although variation among individuals suggests that motion artifacts or muscle electrical activity also contributed. Minimal heat loss occurred at the shaved implantation site, and subcutaneous temperature stabilized within 2–5 days. Conclusions Overall, the study demonstrates that implantable HRT loggers are an effective tool for long-term recording of heart rate and sub-cutaneous temperature in wild polar bears. Future deployments should prioritize longer ECG durations (10 s) to maximize data quality.

Authors

Institutions

Publication Details

Journal
Animal Biotelemetry
Published
2026-04-25
DOI
https://doi.org/10.1186/s40317-026-00459-z
Primary Topic
Marine animal studies overview
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse of the Arctic: feasibility of long-term physiological monitoring of polar bears using implantable heart rate and temperature loggers

Marie‐Anne Blanchet, Ásgeir Bjarnason, Magnus Andersen, Jon Aars et al.
Animal Biotelemetry
Marine animal studies overview
article

Pulse of the Arctic: feasibility of long-term physiological monitoring of polar bears using implantable heart rate and temperature loggers

Marie‐Anne Blanchet, Ásgeir Bjarnason, Magnus Andersen, Jon Aars, Rolf-Arne Ølberg
article en

Abstract

Abstract Background Energy expenditure shapes key biological functions in animals, including reproduction, growth, foraging, and survival. Yet quantifying energy expenditure over long periods in wildlife, especially in remote Arctic environments, remains difficult. Traditional approaches of estimating metabolic rate using heart rate (HR) measurements by external devices have substantial limitations, whereas implantable biologgers offer a promising alternative. This study assesses for the first time the feasibility of using implantable heart rate and temperature (HRT) loggers in wild adult female polar bears (Ursus maritimus) equipped with GPS collars in the Svalbard Archipelago. Results Five bears were surgically implanted with HRT devices that recorded HR and body temperature every 15 min for more than a year, along with short (4 s) and long (10 s) electrocardiograms (ECG) every 6 h and 18 h, respectively. The females were tracked using GPS collars throughout the study. All implantation procedures were completed safely, and device retrieval the following year revealed no lasting health effects. The loggers performed reliably, with 82% of HR data classified as high quality. Manual validation of ECGs increased data retention by 1.7% and verified the accuracy of extreme HR values (11 to 178 BPM). Lower-quality data were generally associated with shorter ECG durations and low HR, although variation among individuals suggests that motion artifacts or muscle electrical activity also contributed. Minimal heat loss occurred at the shaved implantation site, and subcutaneous temperature stabilized within 2–5 days. Conclusions Overall, the study demonstrates that implantable HRT loggers are an effective tool for long-term recording of heart rate and sub-cutaneous temperature in wild polar bears. Future deployments should prioritize longer ECG durations (10 s) to maximize data quality.

Animal Biotelemetry
Star-Oddi (Iceland) (IS), Ansgar University College (NO), UiT The Arctic University of Norway (NO), Norwegian Polar Institute (NO)
Universitetet i Tromsø
Openalex Percentile: Top 5%
Marine animal studies overview
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.