Clinical outcomes of a novel sternal closure technique using tension-fixed titanium cables and a biodegradable poly-lactic acid mesh plate

Sternal closure after median sternotomy is a fundamental surgical procedure in cardiovascular surgery, and inadequate fixation may result in complications such as pain, bleeding, infection and sternal dehiscence. We developed a new sternal closure technique using tension-fixed titanium cables combined with a biodegradable poly-lactic acid (PLA) mesh plate. This study aimed to evaluate the clinical effectiveness of this new technique in terms of pain reduction, sternal displacement, and postoperative recovery compared with conventional wire cerclage. A total of 250 patients who underwent median sternotomy between August 2019 and January 2025 were enrolled and categorised into two groups. Group N (n = 125) received a new technique using titanium cables and a PLA mesh plate, and Group O (n = 125) underwent conventional wire cerclage. Postoperative pain was assessed using the Numerical Rating Scale (NRS), and sternal displacement was evaluated using computed tomography. Clinical outcomes, including drainage volume, intubation time, intensive care unit (ICU)/hospital stay, and surgical site infections, were also compared. Group N had significantly lower NRS scores at 1 week (1.0 [1.0–2.0] vs. 2.0 [1.0–3.0], p = 0.02) and at discharge (1.0 [0–2.0] vs. 1.0 [1.0–2.0], p = 0.01). Transverse and longitudinal sternal displacements were significantly reduced in Group N (0.27 ± 0.71 mm vs. 0.66 ± 1.01 mm, p < 0.001; 0.51 ± 0.78 mm vs. 0.74 ± 1.07 mm, p = 0.04, respectively). Further, Group N showed lower drainage volume within 12 h postoperatively (p = 0.02), shorter time to extubation (p = 0.02), reduced ICU (p = 0.01) and hospital (p = 0.005) stay, and a lower incidence of deep sternal wound infection (0% vs. 3.2%, p = 0.04). The new sternal closure technique using tension-fixed titanium cables with a PLA mesh plate significantly improved postoperative outcomes compared with conventional wire cerclage. It effectively enhances sternal stability, reduces pain and bleeding, shortens recovery time, and lowers the risk of serious complications.

Authors

Institutions

Publication Details

Journal
Journal of Cardiothoracic Surgery
Published
2026-04-25
DOI
https://doi.org/10.1186/s13019-026-04194-7
Primary Topic
Surgical site infection prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical outcomes of a novel sternal closure technique using tension-fixed titanium cables and a biodegradable poly-lactic acid mesh plate

Hironori Izutani, Yuka Suemitsu, Takuma Fukunishi, Kenji Namiguchi et al.
Journal of Cardiothoracic Surgery
Surgical site infection prevention
article

Clinical outcomes of a novel sternal closure technique using tension-fixed titanium cables and a biodegradable poly-lactic acid mesh plate

Hironori Izutani, Yuka Suemitsu, Takuma Fukunishi, Kenji Namiguchi, Masayuki Nagaoka, Hiroshi Sakamoto, Tomohisa Sakaue, Hirotsugu Kurobe, Nanae Hiyama, Noritaka Ota, Tomohide Higaki, Takashi Nishimura
article en

Abstract

Sternal closure after median sternotomy is a fundamental surgical procedure in cardiovascular surgery, and inadequate fixation may result in complications such as pain, bleeding, infection and sternal dehiscence. We developed a new sternal closure technique using tension-fixed titanium cables combined with a biodegradable poly-lactic acid (PLA) mesh plate. This study aimed to evaluate the clinical effectiveness of this new technique in terms of pain reduction, sternal displacement, and postoperative recovery compared with conventional wire cerclage. A total of 250 patients who underwent median sternotomy between August 2019 and January 2025 were enrolled and categorised into two groups. Group N (n = 125) received a new technique using titanium cables and a PLA mesh plate, and Group O (n = 125) underwent conventional wire cerclage. Postoperative pain was assessed using the Numerical Rating Scale (NRS), and sternal displacement was evaluated using computed tomography. Clinical outcomes, including drainage volume, intubation time, intensive care unit (ICU)/hospital stay, and surgical site infections, were also compared. Group N had significantly lower NRS scores at 1 week (1.0 [1.0–2.0] vs. 2.0 [1.0–3.0], p = 0.02) and at discharge (1.0 [0–2.0] vs. 1.0 [1.0–2.0], p = 0.01). Transverse and longitudinal sternal displacements were significantly reduced in Group N (0.27 ± 0.71 mm vs. 0.66 ± 1.01 mm, p < 0.001; 0.51 ± 0.78 mm vs. 0.74 ± 1.07 mm, p = 0.04, respectively). Further, Group N showed lower drainage volume within 12 h postoperatively (p = 0.02), shorter time to extubation (p = 0.02), reduced ICU (p = 0.01) and hospital (p = 0.005) stay, and a lower incidence of deep sternal wound infection (0% vs. 3.2%, p = 0.04). The new sternal closure technique using tension-fixed titanium cables with a PLA mesh plate significantly improved postoperative outcomes compared with conventional wire cerclage. It effectively enhances sternal stability, reduces pain and bleeding, shortens recovery time, and lowers the risk of serious complications.

Journal of Cardiothoracic Surgery
Ehime Medical Center (JP), Ehime University Hospital (JP), Ehime University (JP)
Openalex Percentile: Top 6%
Surgical site infection prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.