A multi-institutional EPID-based 3D dose reconstruction model in a virtual phantom for standardized patient QA, benchmarking and auditing for stereotactic radiosurgery

Background and Purpose: For single-isocentre multi-target (SIMT) stereotactic radiosurgery (SRS), benchmarking, auditing and inter-institutional standardisation of dose verification remain challenging as they require specialized equipment and expertise. This work aims to develop and validate an electronic portal imaging device (EPID)-based technique to determine 3D dose in a virtual spherical phantom which is applicable across institutions for SIMT SRS dose verification. Materials and Methods: and depths from 1.5-20 cm. Matching EPID images were collected at each centre. Utilising the average-centre data, jaw-derived and MLC-derived models were created to convert EPID images to three-dimensional dose in a virtual spherical phantom. Models were validated by comparing EPID-derived dose with film in a three-dimensional-printed spherical phantom for 11 non-coplanar SIMT SRS plans. Results: Output factors estimated from EPID-to-dose models were within 1.8% (jaw-derived) and 1.0% (MLC-derived) of measured factors at 10 cm depth. For SIMT SRS plans, target dose differences were -0.3 ± 2.4% (mean ± standard deviation) and gamma pass rates were 99.6 ± 1.7% (5%/1.5 mm) for the jaw-derived model compared to film. For the MLC-derived model, -0.2 ± 2.1% dose differences and 99.7 ± 1.2% pass rates (5%/1.5 mm) were achieved. Conclusions: The EPID-based three-dimensional dose reconstruction method was modelled using multi-institutional data and validated for static and SIMT SRS deliveries. This method requires no specialised equipment and can be applied across institutions for benchmarking, auditing and standardised patient-specific quality assurance for SRS.

Authors

Institutions

Publication Details

Journal
Physics and Imaging in Radiation Oncology
Published
2026-04-25
DOI
https://doi.org/10.1016/j.phro.2026.100979
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A multi-institutional EPID-based 3D dose reconstruction model in a virtual phantom for standardized patient QA, benchmarking and auditing for stereotactic radiosurgery

Baozhou Sun, Andrew Dipuglia, Ching‐Ling Teng, Richard A. Popple et al.
Physics and Imaging in Radiation Oncology
Advanced Radiotherapy Techniques
article

A multi-institutional EPID-based 3D dose reconstruction model in a virtual phantom for standardized patient QA, benchmarking and auditing for stereotactic radiosurgery

Baozhou Sun, Andrew Dipuglia, Ching‐Ling Teng, Richard A. Popple, Lim Seng-Boh, Michael P. Barnes, Gemma Warner, Cameron Stanton, Emily Searle, Ashley Cullen, Peter Greer, Benjamin Zwan, Juan‐Francisco Calvo‐Ortega, Sergei Zavgorodni, Matthew Schmidt, Conor K McGarry, Andrew Cousins, Xiaodong Zhao, Victoria Robinson, Michael Lovelock
article en

Abstract

Background and Purpose: For single-isocentre multi-target (SIMT) stereotactic radiosurgery (SRS), benchmarking, auditing and inter-institutional standardisation of dose verification remain challenging as they require specialized equipment and expertise. This work aims to develop and validate an electronic portal imaging device (EPID)-based technique to determine 3D dose in a virtual spherical phantom which is applicable across institutions for SIMT SRS dose verification. Materials and Methods: and depths from 1.5-20 cm. Matching EPID images were collected at each centre. Utilising the average-centre data, jaw-derived and MLC-derived models were created to convert EPID images to three-dimensional dose in a virtual spherical phantom. Models were validated by comparing EPID-derived dose with film in a three-dimensional-printed spherical phantom for 11 non-coplanar SIMT SRS plans. Results: Output factors estimated from EPID-to-dose models were within 1.8% (jaw-derived) and 1.0% (MLC-derived) of measured factors at 10 cm depth. For SIMT SRS plans, target dose differences were -0.3 ± 2.4% (mean ± standard deviation) and gamma pass rates were 99.6 ± 1.7% (5%/1.5 mm) for the jaw-derived model compared to film. For the MLC-derived model, -0.2 ± 2.1% dose differences and 99.7 ± 1.2% pass rates (5%/1.5 mm) were achieved. Conclusions: The EPID-based three-dimensional dose reconstruction method was modelled using multi-institutional data and validated for static and SIMT SRS deliveries. This method requires no specialised equipment and can be applied across institutions for benchmarking, auditing and standardised patient-specific quality assurance for SRS.

Physics and Imaging in Radiation OncologyVol. 39
Queen's University Belfast (GB), Island Health (CA), Belfast Health and Social Care Trust (GB), The University of Sydney (AU), Northwell Health (US), Memorial Sloan Kettering Cancer Center (US), Baylor College of Medicine (US), Washington University in St. Louis (US), University of Victoria (CA), Gosford Hospital (AU), Christchurch Hospital (NZ), University of Alabama at Birmingham (US), Cooperative Trials Group for Neuro-Oncology (AU), Chris O’Brien Lifehouse (AU), Mount Sinai Hospital (US), Hospital Quirónsalud Barcelona (ES), The Northern Ireland Cancer Centre (GB), Calvary Mater Newcastle Hospital (AU), University of Newcastle Australia (AU)
Openalex Percentile: Top 13%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.