Enhanced torque control of a grid-connected DFIG wind turbine system under variable wind speed conditions
This paper describes an appropriate hybrid control mechanism to enhance the turbine peak output torque of a DFIG-based grid-connected wind energy conversion system at variable wind speed conditions. These sudden variations pose a critical challenge to maximizing output torque and other associated optimal parameters. To address the identified research gaps, this study aimed to design a novel hybrid ANFIS-PI controller for a back-to-back converter, confirming superior efficiency and responsiveness. The recent MATLAB–Simulink model simulation results illustrate that an intended ANFIS-PI controller achieved a peak output torque of 13.31 kNm, compared with 13.25 kNm for the FLC-PI controller, both evaluated against a PI-controller benchmark of 12.09 kNm. To achieve these results by enhancing the maximum power coefficient to 0.55 by the ANFIS-PI, compared with 0.547 from the FLC-PI and 0.4801 for the PI controller, at an optimal blade angle of 0° and the maximum speed of 12.5 m/s.
Authors
- Yoseph Mekonnen Abebe (ORCID: https://orcid.org/0000-0001-7786-8340)
- Milkias Berhanu Tuka (ORCID: https://orcid.org/0000-0001-7223-9238)
- Likenesh Walle Biyazne
- Anatoli Wellhöfer
Institutions
- Technical University of Applied Sciences Würzburg-Schweinfurt (DE)
- Addis Ababa Science and Technology University (ET)
Publication Details
- Journal
- Wind Engineering
- Published
- 2026-04-25
- DOI
- https://doi.org/10.1177/0309524x261442703
- Primary Topic
- Wind Turbine Control Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00