Supervised vs. unsupervised radiomics reproducibility across dose-level variations and partial volume correction methods in total-body PET imaging

Background and objective : To provide a systematic reproducibility analysis of radiomic features in total-body [ 18 F]-FDG PET imaging, assessing the effects of dose variation, partial volume correction (PVC), and harmonization. Methods : A dual-center total-body [ 18 F]-FDG PET dataset (n = 170 scans, 85 per center) acquired on the uEXPLORER and Biograph Vision Quadra systems was retrospectively subsampled from list-mode data to simulate four relative count levels (100%, 50%, 10%, 2%). PVC was performed using Richardson–Lucy (RL) and reblurred Van-Cittert (RVC) deconvolution, with non-PVC images serving as reference. Radiomic features (n = 93) were extracted from PET images. ComBat harmonization was applied across centers. Reproducibility was assessed using: (i) intraclass correlation coefficient (ICC), (ii) PCA/UMAP-based drift distances, and (iii) Linear Discriminant Analysis (LDA). Results : Across-dose ICC showed that > 60% of features fell into the Poor category (ICC < 0.5), with only 1–3 features (<3%) achieving Excellent reproducibility (ICC ≥ 0.9). Drift distances increased with dose reduction, from mean 5.98 at 50% to > 11 at 2%, reflecting strong dose dependence. PVC offered limited benefit: RL slightly outperformed non-PVC, whereas RVC consistently induced the largest drifts (up to 61% higher). ComBat harmonization failed to improve stability and occasionally increased variability (+13% for RL at 50%). LDA confirmed these findings: dose levels showed measurable separability in discriminant space, whereas PVC methods overlapped substantially, and harmonization effects were negligible, with before–after conditions appearing nearly indistinguishable. Conclusions: Radiomics reproducibility in total-body PET is primarily driven by dose level, with PVC effects being task-dependent and harmonization providing negligible benefit.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-04-25
DOI
https://doi.org/10.1016/j.bspc.2026.110307
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Supervised vs. unsupervised radiomics reproducibility across dose-level variations and partial volume correction methods in total-body PET imaging

Habib Zaidi, Mohammad-Saber Azimi, Maryam Cheraghi, Fatemeh MahdiMaleki et al.
Biomedical Signal Processing and Control
Radiomics and Machine Learning in Medical Imaging
article

Supervised vs. unsupervised radiomics reproducibility across dose-level variations and partial volume correction methods in total-body PET imaging

Habib Zaidi, Mohammad-Saber Azimi, Maryam Cheraghi, Fatemeh MahdiMaleki, Faezeh MahdiMaleki, Abass Alavi
article en

Abstract

Background and objective : To provide a systematic reproducibility analysis of radiomic features in total-body [ 18 F]-FDG PET imaging, assessing the effects of dose variation, partial volume correction (PVC), and harmonization. Methods : A dual-center total-body [ 18 F]-FDG PET dataset (n = 170 scans, 85 per center) acquired on the uEXPLORER and Biograph Vision Quadra systems was retrospectively subsampled from list-mode data to simulate four relative count levels (100%, 50%, 10%, 2%). PVC was performed using Richardson–Lucy (RL) and reblurred Van-Cittert (RVC) deconvolution, with non-PVC images serving as reference. Radiomic features (n = 93) were extracted from PET images. ComBat harmonization was applied across centers. Reproducibility was assessed using: (i) intraclass correlation coefficient (ICC), (ii) PCA/UMAP-based drift distances, and (iii) Linear Discriminant Analysis (LDA). Results : Across-dose ICC showed that > 60% of features fell into the Poor category (ICC < 0.5), with only 1–3 features (<3%) achieving Excellent reproducibility (ICC ≥ 0.9). Drift distances increased with dose reduction, from mean 5.98 at 50% to > 11 at 2%, reflecting strong dose dependence. PVC offered limited benefit: RL slightly outperformed non-PVC, whereas RVC consistently induced the largest drifts (up to 61% higher). ComBat harmonization failed to improve stability and occasionally increased variability (+13% for RL at 50%). LDA confirmed these findings: dose levels showed measurable separability in discriminant space, whereas PVC methods overlapped substantially, and harmonization effects were negligible, with before–after conditions appearing nearly indistinguishable. Conclusions: Radiomics reproducibility in total-body PET is primarily driven by dose level, with PVC effects being task-dependent and harmonization providing negligible benefit.

Biomedical Signal Processing and ControlVol. 122
Obuda University (HU), University of Groningen (NL), Odense University Hospital (DK), Masih Daneshvari Hospital (IR), University Hospital of Geneva (CH), Iran University of Science and Technology (IR), Alzahra University (IR), University of Pennsylvania (US)
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Reduced inequalities
Openalex Percentile: Top 14%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.