ANA fluorescence patterns and low C4 are associated with higher antiphospholipid antibody serological intensity in routine diagnostic testing

OBJECTIVES: To evaluate whether antinuclear antibody (ANA) titre or HEp-2 fluorescence patterns are associated with antiphospholipid antibody (aPL) serological intensity, and to examine component-specific complement abnormalities - particularly low C4 - as laboratory correlates compatible with classical-pathway involvement. METHODS: GPI) antibodies, and ANA. aPL serological intensity was categorised from 0 to 3 (negative to triple-positive) using predefined laboratory cut-offs. ANA patterns were grouped as negative, homogeneous, speckled, or other. Complement variables included low C3, low C4, and combined hypocomplementaemia. Associations were assessed using ordered logistic regression, with Firth bias-reduced logistic regression applied for binary outcomes with sparse events. RESULTS: Overall, 26.5 % of samples (166/626) were aPL-positive, including 1.6 % triple-positive cases (10/626). High-titre ANA (≥1:160) was not associated with higher aPL serological intensity (OR 1.00, 95 % CI 0.51-1.96). In contrast, homogeneous (OR 1.99, 95 % CI 1.26-3.18) and speckled (OR 2.85, 95 % CI 1.66-4.91) ANA patterns were independently associated with higher aPL categories. Low C4, - but not low C3 - was associated with aPL positivity in binary analysis (Firth OR 6.84, p=0.001; low-C4 events n=10). CONCLUSIONS: ANA fluorescence patterns, but not ANA titre, are associated with higher aPL serological intensity, indicating a distinct laboratory serological phenotype. Low C4 shows an association compatible with classical-pathway complement involvement. These findings are observational and require validation in longitudinal studies.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2026-04-20
DOI
https://doi.org/10.1515/cclm-2025-1709
Primary Topic
Systemic Lupus Erythematosus Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANA fluorescence patterns and low C4 are associated with higher antiphospholipid antibody serological intensity in routine diagnostic testing

Olga Striligka, Aikaterini Darivianaki, Christina Kalpadakis, Marilena Kampa et al.
Clinical Chemistry and Laboratory Medicine (CCLM)
Systemic Lupus Erythematosus Research
article

ANA fluorescence patterns and low C4 are associated with higher antiphospholipid antibody serological intensity in routine diagnostic testing

Olga Striligka, Aikaterini Darivianaki, Christina Kalpadakis, Marilena Kampa, Eleni Nioti, Antonios Dilintas, Nikolaos Androulakis, Theodosia Iatridi, Fotini Nistikaki, Anastasia Papadopoulou
article en

Abstract

OBJECTIVES: To evaluate whether antinuclear antibody (ANA) titre or HEp-2 fluorescence patterns are associated with antiphospholipid antibody (aPL) serological intensity, and to examine component-specific complement abnormalities - particularly low C4 - as laboratory correlates compatible with classical-pathway involvement. METHODS: GPI) antibodies, and ANA. aPL serological intensity was categorised from 0 to 3 (negative to triple-positive) using predefined laboratory cut-offs. ANA patterns were grouped as negative, homogeneous, speckled, or other. Complement variables included low C3, low C4, and combined hypocomplementaemia. Associations were assessed using ordered logistic regression, with Firth bias-reduced logistic regression applied for binary outcomes with sparse events. RESULTS: Overall, 26.5 % of samples (166/626) were aPL-positive, including 1.6 % triple-positive cases (10/626). High-titre ANA (≥1:160) was not associated with higher aPL serological intensity (OR 1.00, 95 % CI 0.51-1.96). In contrast, homogeneous (OR 1.99, 95 % CI 1.26-3.18) and speckled (OR 2.85, 95 % CI 1.66-4.91) ANA patterns were independently associated with higher aPL categories. Low C4, - but not low C3 - was associated with aPL positivity in binary analysis (Firth OR 6.84, p=0.001; low-C4 events n=10). CONCLUSIONS: ANA fluorescence patterns, but not ANA titre, are associated with higher aPL serological intensity, indicating a distinct laboratory serological phenotype. Low C4 shows an association compatible with classical-pathway complement involvement. These findings are observational and require validation in longitudinal studies.

Clinical Chemistry and Laboratory Medicine (CCLM)
University Hospital of Heraklion (GR)
Openalex Percentile: Top 10%
Systemic Lupus Erythematosus Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.