Constraints on implant design resulting from the needs of surgical placement—implications for implantable artificial muscles

Abstract Design of a medical implant needs to ensure the device can be positioned accurately and removed subsequently if needed. This necessitates specific design considerations for implantation. This review is an opinion paper considering how an operation to introduce an implant into a patient may affect design, focusing on development of implantable artificial muscles (IAMs). Compatibility with endoscopic ports or the Seldinger technique will help deliver treatment with shorter hospital stay and quicker recovery. This means an IAM device has to have configurations to suit both deployment and use. Replacement of the device or removal as an emergency means it must be easy to extract without damage to the patient’s tissues, using standard surgical equipment. The implant has to be compatible with processes for sterilizing medical devices. But design of the packaging of the implant is equally important, since transfer of the device from its sterile-packaged storage state to the operating table for deployment into a patient is a vulnerable process in which contamination can occur. Implant surgery is a high-risk healthcare intervention. Those developing IAMs should consider aspects relating to surgical approach, deployment, wear, fixation, avoidance of perioperative complications and subsequent removal.

Authors

Institutions

Publication Details

Journal
Interface Focus
Published
2026-04-24
DOI
https://doi.org/10.1098/rsfs.2025.0048
Citations
1
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
15.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Constraints on implant design resulting from the needs of surgical placement—implications for implantable artificial muscles

Marcus J. Drake, Alex D. Liddle, Martin Birchall
1 citations
Interface Focus
Medical Device Sterilization and Disinfection
15.92
article

Constraints on implant design resulting from the needs of surgical placement—implications for implantable artificial muscles

Marcus J. Drake, Alex D. Liddle, Martin Birchall
article en
1 citations

Abstract

Abstract Design of a medical implant needs to ensure the device can be positioned accurately and removed subsequently if needed. This necessitates specific design considerations for implantation. This review is an opinion paper considering how an operation to introduce an implant into a patient may affect design, focusing on development of implantable artificial muscles (IAMs). Compatibility with endoscopic ports or the Seldinger technique will help deliver treatment with shorter hospital stay and quicker recovery. This means an IAM device has to have configurations to suit both deployment and use. Replacement of the device or removal as an emergency means it must be easy to extract without damage to the patient’s tissues, using standard surgical equipment. The implant has to be compatible with processes for sterilizing medical devices. But design of the packaging of the implant is equally important, since transfer of the device from its sterile-packaged storage state to the operating table for deployment into a patient is a vulnerable process in which contamination can occur. Implant surgery is a high-risk healthcare intervention. Those developing IAMs should consider aspects relating to surgical approach, deployment, wear, fixation, avoidance of perioperative complications and subsequent removal.

Interface FocusVol. 16(1)
NIHR Imperial Biomedical Research Centre (GB), The London College (GB), University College London (GB), Imperial College London (GB)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 1%
Medical Device Sterilization and Disinfection
15.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.