Q.Clear reconstruction shortening the scanning time for 11C-CFT brain PET/MR imaging

As a tracer in brain PET imaging for diagnosis of Parkinson’s disease (PD), the application of 11C-methyl-N-2β-carbomethoxy-3β-(4-fluorophenyl)-tropane (11C-CFT) is limited due to its short half-life. This study aims to explore the feasibility of using Q.Clear reconstruction to reduce the scanning time of 11C-CFT brain PET imaging. We retrospectively enrolled 43 patients who underwent 11C-CFT PET/MRI examination. Their image data was reconstructed using classical ordered subset expectation maximization (OSEM) with 20 min and Q.Clear with 5, 10, 15, 20 min of scanning time (QC05, QC10, QC15, QC20). Subsequently, subjective quality assessment and semi-quantitative assessment were employed across the five reconstruction groups. Subjective image assessment included overall image quality, image noise and lesion depiction. Signal-to-noise ratio (SNR), signal-to-background ratio (SBR) and dopamine transporters (DAT) binding rate were measured in semi-quantitative assessment. In subjective assessment, all Q.Clear groups showed image quality and noise comparable or superior to OSEM. However, QC05 group received significantly lower overall image quality scores than QC10, QC15, QC20 (all P < 0.05). In several QC05 cases, both readers noted conspicuous signal absence with locational and uptake inconsistencies versus OSEM, leading to diagnostic discrepancy. By contrast, QC10, QC15, QC20 provided lesion visibility equivalent to the OSEM reference. Semi‑quantitative analysis indicated no significant differences among all groups in SNR, SBR, or DAT binding rate (all P > 0.05). The Q.Clear reconstruction demonstrates reliable performance in the quantitative assessment of 11C-CFT brain PET imaging, therefore can shorten scanning time to at least 10 min under the premise of meeting clinical diagnostic requirements.

Authors

Institutions

Publication Details

Journal
EJNMMI Physics
Published
2026-04-24
DOI
https://doi.org/10.1186/s40658-026-00878-0
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Q.Clear reconstruction shortening the scanning time for 11C-CFT brain PET/MR imaging

W Zhou, X C Li, X Chen, Renxiang Xia et al.
EJNMMI Physics
Medical Imaging Techniques and Applications
article

Q.Clear reconstruction shortening the scanning time for 11C-CFT brain PET/MR imaging

W Zhou, X C Li, X Chen, Renxiang Xia, Le Chen, He Long, Yun Yao, Wenjie Gong, Dan Wang
article en

Abstract

As a tracer in brain PET imaging for diagnosis of Parkinson’s disease (PD), the application of 11C-methyl-N-2β-carbomethoxy-3β-(4-fluorophenyl)-tropane (11C-CFT) is limited due to its short half-life. This study aims to explore the feasibility of using Q.Clear reconstruction to reduce the scanning time of 11C-CFT brain PET imaging. We retrospectively enrolled 43 patients who underwent 11C-CFT PET/MRI examination. Their image data was reconstructed using classical ordered subset expectation maximization (OSEM) with 20 min and Q.Clear with 5, 10, 15, 20 min of scanning time (QC05, QC10, QC15, QC20). Subsequently, subjective quality assessment and semi-quantitative assessment were employed across the five reconstruction groups. Subjective image assessment included overall image quality, image noise and lesion depiction. Signal-to-noise ratio (SNR), signal-to-background ratio (SBR) and dopamine transporters (DAT) binding rate were measured in semi-quantitative assessment. In subjective assessment, all Q.Clear groups showed image quality and noise comparable or superior to OSEM. However, QC05 group received significantly lower overall image quality scores than QC10, QC15, QC20 (all P < 0.05). In several QC05 cases, both readers noted conspicuous signal absence with locational and uptake inconsistencies versus OSEM, leading to diagnostic discrepancy. By contrast, QC10, QC15, QC20 provided lesion visibility equivalent to the OSEM reference. Semi‑quantitative analysis indicated no significant differences among all groups in SNR, SBR, or DAT binding rate (all P > 0.05). The Q.Clear reconstruction demonstrates reliable performance in the quantitative assessment of 11C-CFT brain PET imaging, therefore can shorten scanning time to at least 10 min under the premise of meeting clinical diagnostic requirements.

EJNMMI Physics
Army Medical University (CN), Chongqing University (CN), Daping Hospital (CN), Third People 's Hospital of Chongqing (CN), The Affiliated Yongchuan Hospital of Chongqing Medical University (CN), Chongqing Medical University (CN)
Natural Science Foundation of Chongqing
Openalex Percentile: Top 4%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.