A Low-Complexity CW Radar for Detecting High-Precision Tiny Vibration

Research on methods for detecting microwave-based noncontact vibration has garnered significant attention in recent years. To simplify system complexity and reduce costs, which would enable broader application of radar technology in daily life, we propose a low-complexity, high-precision continuous-wave (CW) radar system for noncontact vibration detection. This system employs a hardware-based approach for phase comparison to extract vibration information, enabling simultaneous detection of both vibration amplitude and frequency under a CW radar architecture. In this study, we establish a phase discrimination error model to characterize the inconsistent detection sensitivity of the hardware phase comparator in different phase intervals, and we further propose a phase compensation scheme to mitigate the nonlinearity of phase discrimination and the “null-point” problem in continuous phase comparison, consequently improving the sensitivity and precision of the proposed radar system. Through loudspeaker vibration and experiments on human vital signs, the system maintains a vibration amplitude detection accuracy above 90.3% within 1.8 m while achieving respiratory rate and heartbeat rate detection accuracies of 96.34% and 98.02%, respectively.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-04-24
DOI
https://doi.org/10.3390/electronics15091820
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low-Complexity CW Radar for Detecting High-Precision Tiny Vibration

Xiaoyue Wei, Pengsong Duan, Yangjie Cao, Chao Wang et al.
Electronics
Non-Invasive Vital Sign Monitoring
article

A Low-Complexity CW Radar for Detecting High-Precision Tiny Vibration

Xiaoyue Wei, Pengsong Duan, Yangjie Cao, Chao Wang, Yue Wang, Jinpeng Shi, Z. Jiao
article en

Abstract

Research on methods for detecting microwave-based noncontact vibration has garnered significant attention in recent years. To simplify system complexity and reduce costs, which would enable broader application of radar technology in daily life, we propose a low-complexity, high-precision continuous-wave (CW) radar system for noncontact vibration detection. This system employs a hardware-based approach for phase comparison to extract vibration information, enabling simultaneous detection of both vibration amplitude and frequency under a CW radar architecture. In this study, we establish a phase discrimination error model to characterize the inconsistent detection sensitivity of the hardware phase comparator in different phase intervals, and we further propose a phase compensation scheme to mitigate the nonlinearity of phase discrimination and the “null-point” problem in continuous phase comparison, consequently improving the sensitivity and precision of the proposed radar system. Through loudspeaker vibration and experiments on human vital signs, the system maintains a vibration amplitude detection accuracy above 90.3% within 1.8 m while achieving respiratory rate and heartbeat rate detection accuracies of 96.34% and 98.02%, respectively.

ElectronicsVol. 15(9)
Zhengzhou University (CN), Second Affiliated Hospital of Zhengzhou University (CN)
Reduced inequalities
Openalex Percentile: Top 9%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.