Biomechanical effect of implant thickness and screw diameter on CFR-PEEK subperiosteal implants: a three-dimensional finite element analysis

Objectives: The aim of this study is to evaluate the effects of subperiosteal implant framework thickness and screw diameter on the biomechanical behavior of patient-specific subperiosteal implant systems made from 60% Carbon Fiber Reinforced Polyetheretherketone (CFR-PEEK) using three-dimensional finite element analysis (FEA). Materials and Methods: Four three-dimensional FEA models were constructed using a single patient-specific maxillary geometry derived from computed tomography (CT) data in these models, two implant framework thicknesses (T:1.0 mm and 1.5 mm) and two screw diameters (SD: 1.5 mm and 2.0 mm) were analyzed in combination using 60% CFR-PEEK biomaterial. Three loading scenarios were simulated: (1) Bilateral 150 N perpendicular force to the buccal cusp tips of the first and second premolars and the first molar, (2) Unilateral 100 N oblique force at a 30° angle from buccal to palatal to the same areas, and (3) Bilateral 150 N perpendicular force to the central and lateral incisors. Total displacement values, maximum and minimum principal stresses in the bone; Von Mises stresses in the bone, subperiosteal implant, abutment, and metal framework were evaluated. Results: Increasing the subperiosteal implant framework thickness was found to reduce stresses that were particularly elevated in the posterior maxillary region under various loading conditions, while simultaneously increasing the stresses on the subperiosteal implant and metal framework. Increasing the screw diameter decreased the stresses on both the bone and implant, but resulted in higher stress concentrations within the metal framework. The 60% CFR-PEEK material with a high elastic modulus reduced stresses in the bone, but the concentration of applied loads in the implant body and metal framework led to higher stress values in these structures. Conclusion: Subperiosteal implant framework thickness, screw diameter, and material stiffness appear to have a significant influence on stress distribution and overall stability in subperiosteal implant systems. Although this study is limited to finite element analysis, the findings suggest that CFR-PEEK based designs may satisfy the essential biomechanical requirements for clinical application.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-24
DOI
https://doi.org/10.1038/s41598-026-49671-0
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical effect of implant thickness and screw diameter on CFR-PEEK subperiosteal implants: a three-dimensional finite element analysis

Başak KESKİN YALÇIN, Eda Etik
Scientific Reports
Dental Implant Techniques and Outcomes
article

Biomechanical effect of implant thickness and screw diameter on CFR-PEEK subperiosteal implants: a three-dimensional finite element analysis

Başak KESKİN YALÇIN, Eda Etik
article en

Abstract

Objectives: The aim of this study is to evaluate the effects of subperiosteal implant framework thickness and screw diameter on the biomechanical behavior of patient-specific subperiosteal implant systems made from 60% Carbon Fiber Reinforced Polyetheretherketone (CFR-PEEK) using three-dimensional finite element analysis (FEA). Materials and Methods: Four three-dimensional FEA models were constructed using a single patient-specific maxillary geometry derived from computed tomography (CT) data in these models, two implant framework thicknesses (T:1.0 mm and 1.5 mm) and two screw diameters (SD: 1.5 mm and 2.0 mm) were analyzed in combination using 60% CFR-PEEK biomaterial. Three loading scenarios were simulated: (1) Bilateral 150 N perpendicular force to the buccal cusp tips of the first and second premolars and the first molar, (2) Unilateral 100 N oblique force at a 30° angle from buccal to palatal to the same areas, and (3) Bilateral 150 N perpendicular force to the central and lateral incisors. Total displacement values, maximum and minimum principal stresses in the bone; Von Mises stresses in the bone, subperiosteal implant, abutment, and metal framework were evaluated. Results: Increasing the subperiosteal implant framework thickness was found to reduce stresses that were particularly elevated in the posterior maxillary region under various loading conditions, while simultaneously increasing the stresses on the subperiosteal implant and metal framework. Increasing the screw diameter decreased the stresses on both the bone and implant, but resulted in higher stress concentrations within the metal framework. The 60% CFR-PEEK material with a high elastic modulus reduced stresses in the bone, but the concentration of applied loads in the implant body and metal framework led to higher stress values in these structures. Conclusion: Subperiosteal implant framework thickness, screw diameter, and material stiffness appear to have a significant influence on stress distribution and overall stability in subperiosteal implant systems. Although this study is limited to finite element analysis, the findings suggest that CFR-PEEK based designs may satisfy the essential biomechanical requirements for clinical application.

Scientific Reports
Istanbul University (TR)
Openalex Percentile: Top 6%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.